background image

Operation

Periodic cleaning of the unit is recommended to ensure optimum performance.

Disconnect the electrical supply.
Remove the two cover-mounting screws.
Remove the cover.
Clean all dust lint from the interior of the dryer.

Replace the cover. Do not over tighten the screws.

Wipe the cover with a damp cloth and mild 
cleaning solution. Do not Soak. Never use 
abrasives to clean the cover.

Cleaning and Maintenance

50" 

3

Recommended mounting heights

from bottom edge of dryer above finished floor (AFF)

                     See Mounting Template & Installation Guide (MT & IG) 

                 1207101509 

(Supplied with unit)

Men
Women
Children 4-7 years
Children 8-10 years
Children 11-13 years
Children 14-16 years
Handicaped

(1270 mm)

47" 

(1194 mm)

35" 

(889 mm)

39" 

(991 mm)

43" 

(1092 mm)

47" 

(1194 mm)

40" 

(1016 mm)

All Approaches 

48" 

(1219 mm)

Reference 

ADAAG

Reach LIMIT (unrestricted)

AFF (maximum)

Circuit Diagram

S

hake excess water from hands. 

P

lace hands under the nozzle and dryer 

automatically starts operation. 

R

ub hands lightly and rapidly under the nozzle.

D

ryer stops when hands are removed from 

sensor zone or if maximum time is reached.

Operating Instructions and Parts Manual 

Hand Dryer

Surface-mounted 

ADA

-compliant hand dr yer 

General safety information:

                                Disconnect power at the
service breaker before installing or servicing. 

 

                                

                                This product is intended 
for installation by a qualified service person. 
Use AWG NO. 12 solid conductor for wiring.

                                All units must be supplied 
with a 3-wire service. The ground wire must 
be connected to the dryer's backplate. 

                                Failure to properly ground 
unit could result in severe electrical shock 
and/or death.

Circuit Board Module

Transistor 
Power Switch

MO2 HE2

N

MO1 HE1

L

Transistor 
Power Switch

VR

G

N

L

Thermostat 

Red (110-120~Vac)

 (208-240~ 277~Vac)

/

 

Blue

Black

Black

G/Y

B

lu

e

B

ro

w

n

M
o

to

W
it


T

h

e

r

m
a

S

w
it

c


2

A

Hea

ter W

ith T

her

mo-fuse

FOR SENSOR

SW.

FOR HEATER

White (110-120~Vac)

 (208-240~ 277~Vac)

/

 

Brown

Sensor module

ON

1

VR

FOR MOTOR

G

G/Y

distributed by 

 RESTROOM DIRECT       704 . 937. 2673      

www.

RestroomDirect

.com

Summary of Contents for BluSTORM BOLT

Page 1: ...PALMER FIXTURE COMPANY Palmer Fixture Company P O Box 10887 Green Bay WI 54307 1 800 558 8678 www palmerfixture com uto A distributed by RESTROOM DIRECT 704 937 2673 www RestroomDirect com...

Page 2: ...FF Heating options Range Adjustable by Owner 325 450 W Auto Resetting Thermostat turns heater element off at 185 F 85 C Resets at 167 F 75 C Thermal cut off at 288 F 142 C Less than 15 seconds Infrare...

Page 3: ...or connect supply wires to terminal block where indicated and connect ground wire to base plate with ground screw Connections A Connect the live wire colored Brown Red or Black to the terminal block m...

Page 4: ...under the nozzle and dryer automatically starts operation Rub hands lightly and rapidly under the nozzle Dryer stops when hands are removed from sensor zone or if maximum time is reached Operating In...

Page 5: ...roblem persists disconnect the power and remove the dryer cover and replace CBM IR sensor module First ensure that the breaker supplying the dryer is operational If it is disconnect the power and remo...

Page 6: ...and Parts Manual Hand Dryer Surface mounted ADA compliant hand dryer 5 1 2 3 4 5 6 7 8 9 10 11 13 12 14 15 16 17 18 19 20 21 22 Tools Req d Provided in kit L Wrench Item 23 distributed by RESTROOM DIR...

Page 7: ...bracket Sensor bracket Sensor module Terminal block Rubber grommet Base Mylar shield with LNG marked Cable clamp Grounding screw with cup washer Cable protector Base plate Cover BluStorm Bolt Stainles...

Reviews: