background image

Installation manual 

 

 
 

 

space (1-2 mm) between the floor boards to allow for swelling. But if your climate is warm and dry, you 

can install the boards densely because they will become drier and spaces may appear between them.  
 

Storm braces 

(NB! Not included in some house option kits!) 

Attach the storm braces (if included in 

the s upplied k it) to the i nner s ides of  

the f ront ( 2 un its) and b ack  (2 uni ts) 

walls w ith t he s upplied  bolts.  It i s 

important  for  the  logs  to  be  drilled 

through i n  advance. P lease k eep t he 

distances indicated in the drawing so 

that no pr oblems oc cur du e t o w ood 

swelling or diminishing.  

ADVICE

:  Make  sure  that  the  storm 

braces ar e at tached t o t he  apex  log 

from abov e a nd t o t he m iddle of  t he 

first f ull-length w all  log  from bel ow. I f 

necessary, shorten the upper ends of 

the slats.  
Do not turn the screws tightly so wood 

can further swell or diminish.  
With  the  house  having  settled,  you 

should adj ust t he at tachments s o  the 

wall logs can settle.  

 

 

 

Installation of storm braces: 

 

 

General advice: 

Problem:  

Gaps appear between the wall logs  

Cause:   

Additional details are attached to the house that do not allow wood to    

 

 

swell/diminish. 

Solutions:  

If the door/window is attached to the wall logs with screws/nails, remove these 

screws/nails; 

If the storm brace is screwed on too tightly, loosen its attachment;  

If (rain water) pipes are installed on the wall, loosen their attachments;  

  

Problem:  

The doors and windows become stuck. 

Cause:   

The house/foundation has settled. 

Solution: 

Check whether the house is level. Level the foundation joists and walls. 

Cause: 

The doors and windows have swelled due to moisture.  

Solution:  

Adjust the door and window hinges; if necessary, plane the door or window narrower. 

 
 
 
 

 

 

 

We wish you total success with the garden house installation and much 

joy with this house for many years to come!

 

www.simplylogcabins.co.uk

Summary of Contents for Helena 18.6m2

Page 1: ...Gudrum Buckingham 1 Assembly Instructions w w w s i m p l y l o g c a b i n s c o u k...

Page 2: ...tout change Toutes les revendications ult rieures sont exclues Si une r clamation avait lieu veuillez respecter le d roulement suivant Il vous faudra pr senter v otre commer ant sp cialis ce bulletin...

Page 3: ...___________________________________________ P dansk Kontrol Certifikat Opbevares sikkert Dansk Det k bte hus er fremstillet i overensstemmelse med de h je kvalitets krav Produktet er blevet omhyggelig...

Page 4: ...ved produktet Alle rechten en technische wijzigingen voorbehouden Installation manual Montageanleitung Notice de montage Istruzioni per il montaggio Manual de montaje Monteringsanvisning Installatieg...

Page 5: ...iew complaints if you submit the control number of the house to the seller Peculiarities of wood as a natural material The warranty does not cover Wooden details already painted processed with a wood...

Page 6: ...ation agent and do that namely both inside and outside Otherwise the doors and windows can become twisted After the house assembly is completed we recommend for the conclusive finishing a weather prot...

Page 7: ...ake sure that there are sufficient air apertures under the house floor for ventilation We recommend the following foundation options Strip or spot foundation Foundation from concrete or pavement slabs...

Page 8: ...are always assembled with their tongue upwards If necessary use the hitting block and hammer Never directly hit the tongue with the hammer Install the walls in accordance with the appended wall plans...

Page 9: ...il you reach the window height The wall plans see Technical specifications show how many logs go under the window Install the window similarly with the door Just like the door push the window frame wi...

Page 10: ...e apex or sidewall log somewhat lower Roof Before installing the roof boards make sure that the house is completely level Use the water level to check all walls ATTENTION When placing the roof use a s...

Page 11: ...cm NB Some house options do not include it in the kit Having installed the roof cover material attach the wind braces to the roof and the facia boards to the rafters and upper wall logs Installation...

Page 12: ...ews tightly so wood can further swell or diminish With the house having settled you should adjust the attachments so the wall logs can settle Installation of storm braces General advice Problem Gaps a...

Page 13: ...w w w s i m p l y l o g c a b i n s c o u k...

Page 14: ...w w w s i m p l y l o g c a b i n s c o u k...

Page 15: ...70 846 2 A C B B Side slat Randleiste Baguette en bordure Pos mm mm mm pcs Sis A 19 95 986 2 Sis B 19 70 1072 4 Sis C 19 70 846 2 A C B B Side slat Randleiste Baguette en bordure Pos mm mm mm pcs Sis...

Page 16: ...w w w s i m p l y l o g c a b i n s c o u k...

Page 17: ...w w w s i m p l y l o g c a b i n s c o u k...

Page 18: ...w w w s i m p l y l o g c a b i n s c o u k...

Page 19: ...w w w s i m p l y l o g c a b i n s c o u k...

Page 20: ...w w w s i m p l y l o g c a b i n s c o u k...

Page 21: ...w w w s i m p l y l o g c a b i n s c o u k...

Page 22: ...w w w s i m p l y l o g c a b i n s c o u k...

Page 23: ...w w w s i m p l y l o g c a b i n s c o u k...

Reviews: