Safety  Precautions

Note!

It is required to read the Safety precautions in detail before 
operation. The precautions listed below are all-important for 
safety, please obey without fail.

Make sure  that the fixed ground wire in the building is securely connected to earth.

Wiring tasks should be carried out by qualified electricians only, in addition, they should check the safety conditions 
of power utilization, for example, check if the line capacity is adequate, and check if the power cable is damaged.

Users must not install, repair or relocate the unit.

Improper treatment might lead to the accidents e.g. personal injury caused by fire, electrical shock or unit's falling-
off, and water leakage in the machine. Please contact professional repair and service department of local dealer.

In case the leaked gas is congregated around the machine, there might be the risk of explosion.

The unit  shall not be installed at a spot with potential hazard of leakage of inflammable gas.

If the foundation is unstable, the outdoor unit may drop and cause a casualty accident. so this must be validated carefully.

Make sure that the foundation of installation is stable.

If no electric leakage protection switch is fitted at the beginning of the electric supply, it maybe cause electric shocks or 
fires.

Make sure that the electric leakage protection switch is fixed.

Before cleaning, shut off the electric supply of the unit firstly to avoid injuries caused by fan in operation.

Do not rinse the unit by water because the rinsed unit  may cause electric shock.

Please observe the follow items when cleaning the unit.

Make sure to shut off the electric  supply before maintaining the unit.

Please do not insert fingers or sticks into air outlet or air inlet.

The machine must be transported and stored vertically.

General 

If any abnormity occurs in the unit (such as burned taste inside the unit), cut off the power supply immediately, 
and contact professional repair and service department of local dealer.

The machine must be transported and stored vertically.

Transport and storage

2

Summary of Contents for H Series

Page 1: ...AIR TO WATER HEAT PUMP Installation and Operation Manual DC INVERTER DC INVERTER H series Only Heating series AC series Heating Cooling series HC series Mutifunctional Heating Cooling Hot water...

Page 2: ...Content Safety Precautions Transport and storage General 2 2 2 3 4 11 12 17 19 1 Components Wired LCD Controller Error Code Installation Electric connection Test run...

Page 3: ...ntial hazard of leakage of inflammable gas If the foundation is unstable the outdoor unit may drop and cause a casualty accident so this must be validated carefully Make sure that the foundation of in...

Page 4: ...way valve 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 Position Position Component Component Compressor Gas liquid isolator Water inlet Drain Needle valve AH 6 AH 8 AH 11 AH 15DC 2 3 4 1 5 6 7 19 20...

Page 5: ...hen decrease by 1 5 Key up it s a combined key also but opposite to down key Continuous press then continuous increase short press then increase by 1 6 Key confirm confirm previous operations 7 Key mo...

Page 6: ...can change parameter according to need 3 Procedures of setting parameter change A When in settled mode the unit will operate in accordance with the factory default temperature or last modified temper...

Page 7: ...hes and shows the original or default value default value is 10 followed by press key or to change minimum is 10 maximum no more than 99 after that press key to confirm and exit change mode If didn t...

Page 8: ...rotection temp 100 129 2 57 check set 13 reserved 14 function parameter 0 G3 is seasonal switch valve 1 G3 is solar pre heat valve 0 check set 19 adjust fixed running rate 0 100 HZ 50HZ check set 20 R...

Page 9: ...input status 0 DHW invalid 1 DHW valid check 09 Switch input status 0 G1 valid 1 G1 invalid check 10 high pressure swithc status 0 off 1 on check 11 overcurrent protect switch status 0 off 1 on check...

Page 10: ...pump has water source Icon If it has timer on off setting there is timer icon to indicate 29 C4 water pump 1 run 0 stop check 30 C5 water pump 1 run 0 stop check 31 C6 water pump 1 run 0 stop check 32...

Page 11: ...n to indicate 9 way of communication Non polarity double wire maximum running length is 100 meters and point to point connected Back view of wired controller showed below after change need be repowere...

Page 12: ...Only for Inverter outdoor unit F3 Compressor stopped abnormally Red and shining Only for Inverter outdoor unit F4 outdoor module radiator tansducer error Red and shining Only for Inverter outdoor unit...

Page 13: ...Method 1 12 Method 2 DHW with Room Heating Installation 1 Installationmethod...

Page 14: ...water pump connection can be found in wiring diagram 4 Safety valve air discharge valve should be installed at the top of the circulation system for easy air discharge Air conditoning circulation can...

Page 15: ...Application 1 Application 2 14 Installation 2 Installation with solar assistant...

Page 16: ...ation 15 G2 G1 DHW and AC switching valve G2 Solar automatic selection valve W B D H A 5 4 Unit Dimension mm AH 6 AH 8 AH 11 AH 15 W 1091 1091 D 400 400 H 880 980 Installation 1091 400 780 A 412 412 B...

Page 17: ...of accumulated water in rainy season In snowy areas it is important to prevent accumulated snow from blocking up the air out The recommended height is 20cm to 30cm 2 Drain ditch or other facilities sh...

Page 18: ...s Note Electrical installation and service must be carried out under the supervision of a qualified electrician Electrical installation and wiring must be carried out in accordance with the stipulatio...

Page 19: ...Electric connection Wiring Diagram with built inside water circulation pump Wiring Diagram No built inside water circulation pump 18...

Page 20: ...g all usage and there is no air inside the water system Turn on the heat pump select heating domestic hot water mode check whether the unit is running properly or not the compressor will be started in...

Reviews: