background image

© Copyright 2013, Pall Corporation. Pall, Versalon and 

 are trademarks of Pall Corporation.  

® Indicates a trademark registered in the USA. 

Filtration. Separation. Solution.

SM

 and 

Better Lives. Better Planet

 are service marks of Pall Corporation. 

Visit us on the Web at www.pall.com

Pall Corporation has offices and plants throughout the world. For Pall representatives in your 
area, please go to www.pall.com/contact

Because  of  technological  developments  related  to  the  products,  systems,  and/or  
services described herein, the data and procedures are subject to change without notice. 
Please consult your Pall representative or visit www.pall.com to verify that this information 
remains valid.

25 Harbor Park Drive

Port Washington, NY 11050

+1 800 289 7255  

toll free US

+1 516 484 3600  

telephone

Portsmouth - UK

+44 (0)23 9233 8000 

telephone

+44 (0)23 9233 8811 

fax

Dec 2013. 

Printed in the UK.

 M&ESIG410EN

G410 Series

s e r v i c e  

i n s t r u c t i o n s

G410

V E r S a l o N   H I G H   P r E S S U r E   F I l T E r S

Summary of Contents for Versalon G410 Series

Page 1: ...rom pipe work to avoid static discharge It may be necessary to allow time for the static charge to dissipate before removal Internal static discharge within a charged filter capsule may result in damage to the filter media For further information please contact Pall RECEIPT OF EQUIPMENT WARNING PLEASE CHECK THE PRODUCT LABEL PRIOR TO USE TO ENSURE PRODUCT PART NUMBERS CORRESPOND TO THE APPLICATION...

Page 2: ...talled NOTE The G410 head is supplied if selected with one or two machined differential pressure warning ports fitted with a plastic shipping plug 4 4 Mount the filter assembly in position using four 3 8 16 UNC 2B A ports or M10 x 1 5 C ports bolts in the holes on the head mounting pads Torque bolts to 9 19 ft lb or 12 26 Nm 4 5 Use a check valve downstream of the filter if there is a possibility ...

Page 3: ...ement needs changing or because of high fluid viscosity in cold start conditions 6 2 If visual indicator is fitted and actuates during cold start button changes from white to red it will automatically reset when the normal operating conditions are reached If indicator actuates after resetting replace element 6 3 If the electrical switch actuates e g red light comes on during cold start continue op...

Page 4: ...ver 7 Filter element installation servicing During servicing the external surfaces of the filter assembly must be cleaned to remove any dust deposits Servicing must be conducted using suitable tools that do not present a hazard Servicing must also not be carried out when a potentially explosive atmosphere is present Refer to Product Datasheet TRG410TEN for item numbers for applicable replacement e...

Page 5: ... bowl G400SKZ 1 4 Indicator If fitted See product literature 1 5 Filter element G300 series See product literature 1 Figure 2 G410 section drawing Note All product data can be found at www pall com G410 Versalon HIGH PRESSURE FILTERS EN G410 Series service instructions 1 2 5 3 4 not shown ...

Page 6: ...ase go to www pall com contact Because of technological developments related to the products systems and or services described herein the data and procedures are subject to change without notice Please consult your Pall representative or visit www pall com to verify that this information remains valid 25 Harbor Park Drive Port Washington NY 11050 1 800 289 7255 toll free US 1 516 484 3600 telephon...

Reviews: