G410 Series

s e r v i c e  

i n s t r u c t i o n s

2

Specifications

Housing materials:

Head:  

SG iron to BSEN1563 or equivalent

Bowl:   

Carbon steel to BS970 or equivalent

Bypass Valve    Stainless steel and polyamide

Maximum operating pressure:

420 bar (6,090 psi)

Rated fatigue pressure

0-240 bar (0 - 3,480 PSI) per NFPA T2.6.1 R2-2001 CAT C/90

Proof pressure:

630 bar (9,135 psi)

Typical burst pressure:

1500 bar (21,750 psi)

Element collapse pressure:

G300 element 10 bard (145 psid) differential minimum

Operating temperature range:

-29 °C to 120 °C (-20 °F to 250 °F) with fluorocarbon seals for 

petroleum based and specified synthetic fluids 50 °C (120 °F) 

maximum in HWCF, water-oil emulsion or water glycol

Bypass valve setting options:

4.5 ± 0.5 bard (65 ± 7 psid) differential minimum.

Seals:

The actual operating conditions should be checked by the  

user to ensure that the element, housing and all seals are 

compatible with the fluid and application, and are within local 

safety codes. Please contact Pall or an approved distributor if 

further information is required.

Receipt of equipment

The filter housing, and any optional equipment, may be packed 

if requested by the customer. Unpack carefully and ensure 

optional items are not mislaid in packaging to be discarded.

General sources of information

3.1   For dimensions, operating parameters, assembly/

element part number, ordering information, notes, 

performance data and specifications refer to  

M&EG410EN

3.2    Where under reasonably foreseeable conditions, 

including external fires, the allowable limits could be 

exceeded, suitable protective devices must be installed 

by the customer within the connecting fluid system.

Installation of housing

4.1    The filter can be installed in any attitude, but for ease of 

servicing, it is recommended that it be installed vertically 

with the filter bowl pointing downwards.

4.2    The minimum clearance required for element removal is 

150 mm (6”) for all lengths.

4.3    Threaded differential pressure devices, when fitted,  

must be torque tightened up to 38 ft/lb or 54 Nm.  

Visual indicators should be clearly visible when 

assembly is installed.

NOTE: The G410 head is supplied, if selected, with one or 

two machined differential pressure warning ports fitted with a 

plastic shipping plug.

4.4    Mount the filter assembly in position using four 3/8”-16- 

UNC 2B (‘A’ ports) or M10 x 1.5 (‘C’ ports) bolts in the 

holes on the head mounting pads. Torque bolts to 9-19 

ft/lb or 12-26 Nm.

4.5    Use a check valve downstream of the filter if there is a 

possibility of reverse flow.

4.6    Install the filter housing using additional piping/valving  

to allow complete filter assembly bypass if filter 

maintenance is required without system shutdown.  

This series is not available in a duplex or service  

bypass configuration.

NOTE: Piping supports should be provided as close as is 

practicable to the port connections in order to minimize 

external loads. This filter assembly must not be electronically 

isolated from the user’s earthing system. This filter assembly 

must be earthed by connecting the user’s earthing system to 

one of the inlet/outlet connections.

4.7   Connect lines or hoses to housing inlet and outlet ports. 

The Inlet Port is always on the opposite side to the Indicator 

Port or Pad. See page 5 for details.
Note: Painting of the filter housing is optional. The coating 

on the filter housing is a suitable painting base. Cover the 

differential pressure warning device and nameplate if painting 

of the housing takes place.
4.8   Bleed filters. Open plug at top of filter (if fitted), one and 

a half turns. Jog filter and fill filter until all air bleeds 

through, then tighten the plug. Pressurize system fully 

and check for leaks. If leaks occur, refer to paragraph 5.2.

CAUTION: 
Maximum surge flow should not exceed 1.3 times normal 

flow.

WARNING:

USE FITTINGS OR ADAPTORS COMPATIBLE WITH 

SPECIFIED PORTS SUPPLIED: USE OF INCORRECT 

FITTINGS OR ADAPTORS CAN CAUSE FILTER 

HOUSING OR MANIFOLD FAILURE RESULTING 

IN LOSS OF PRESSURE AND POSSIBLE SYSTEM 

FAILURE OR PERSONAL INJURY.

CAUTION:
Reverse flow through filter element will cause damage.

CAUTION:
Never operate the filter unless the warning device port 

is sealed.

CAUTION:
Failure to bleed the filter housing adequately will 

increase the dissolved air content of the system fluid 

which will shorten fluid life and may cause other 

problems in the system.

G410

V E r S a l o N   H I G H   P r E S S U r E   F I l T E r S

EN

Summary of Contents for Versalon G410 Series

Page 1: ...rom pipe work to avoid static discharge It may be necessary to allow time for the static charge to dissipate before removal Internal static discharge within a charged filter capsule may result in damage to the filter media For further information please contact Pall RECEIPT OF EQUIPMENT WARNING PLEASE CHECK THE PRODUCT LABEL PRIOR TO USE TO ENSURE PRODUCT PART NUMBERS CORRESPOND TO THE APPLICATION...

Page 2: ...talled NOTE The G410 head is supplied if selected with one or two machined differential pressure warning ports fitted with a plastic shipping plug 4 4 Mount the filter assembly in position using four 3 8 16 UNC 2B A ports or M10 x 1 5 C ports bolts in the holes on the head mounting pads Torque bolts to 9 19 ft lb or 12 26 Nm 4 5 Use a check valve downstream of the filter if there is a possibility ...

Page 3: ...ement needs changing or because of high fluid viscosity in cold start conditions 6 2 If visual indicator is fitted and actuates during cold start button changes from white to red it will automatically reset when the normal operating conditions are reached If indicator actuates after resetting replace element 6 3 If the electrical switch actuates e g red light comes on during cold start continue op...

Page 4: ...ver 7 Filter element installation servicing During servicing the external surfaces of the filter assembly must be cleaned to remove any dust deposits Servicing must be conducted using suitable tools that do not present a hazard Servicing must also not be carried out when a potentially explosive atmosphere is present Refer to Product Datasheet TRG410TEN for item numbers for applicable replacement e...

Page 5: ... bowl G400SKZ 1 4 Indicator If fitted See product literature 1 5 Filter element G300 series See product literature 1 Figure 2 G410 section drawing Note All product data can be found at www pall com G410 Versalon HIGH PRESSURE FILTERS EN G410 Series service instructions 1 2 5 3 4 not shown ...

Page 6: ...ase go to www pall com contact Because of technological developments related to the products systems and or services described herein the data and procedures are subject to change without notice Please consult your Pall representative or visit www pall com to verify that this information remains valid 25 Harbor Park Drive Port Washington NY 11050 1 800 289 7255 toll free US 1 516 484 3600 telephon...