background image

F310 Series

s e r v i c e  

i n s t r u c t i o n s

5

10   Parts List

List

Description

Part Number

Quantity

1

 Head

1

2

 Bowl

1

3

 O-ring (head-to-bowl)

G300 SKZ

1

4

Indicator 

If fitted  

See product literature

1

5

Filter element 

G300 series  

See product datasheet 

1

Figure 2 

F310 section drawing

Note: All product data requirements can be found at www.pall.com

Outlet

Inlet

Bypass valve

(3) O-ring

(1) Head

Bowl (2)

(5) Element

V E r S a l o N   M E D I U M   P r E S S U r E   F I l T E r S

F310

EN

Summary of Contents for Versalon F310 Series

Page 1: ...om pipe work to avoid static discharge It may be necessary to allow time for the static charge to dissipate before removal Internal static discharge within a charged filter capsule may result in damage to the filter media For further information please contact Pall RECEIPT OF EQUIPMENT WARNING PLEASE CHECK THE PRODUCT LABEL PRIOR TO USE TO ENSURE PRODUCT PART NUMBERS CORRESPOND TO THE APPLICATION ...

Page 2: ...ndicators should be clearly visible when assembly is installed NOTE The F310 head is supplied with either an unmachined or one machined differential pressure warning port fitted with a plastic shipping plug 4 4 Mount the filter assembly in position using four 3 8 16 UNC 2B A ports or M10 x 1 5 C ports bolts in the holes on the head mounting pads Torque bolts to 9 19 ft lb or 12 26 Nm 4 5 Use a che...

Page 3: ...evices actuate when the element needs changing or because of high fluid viscosity in cold start conditions 6 2 If visual indicator is fitted and actuates during cold start button changes from white to red it will automatically reset when the normal operating condition is reached If indicator actuates after resetting replace element 6 3 If electrical differential device is fitted the use of both po...

Page 4: ...whatsoever 7 Filter element installation servicing During servicing the external surfaces of the filter assembly must be cleaned to remove any dust deposits Servicing must be conducted using suitable tools that do not present a hazard Servicing must also not be carried out when a potentially explosive atmosphere is present Refer to product data sheet for item numbers for applicable replacement ele...

Page 5: ...ead to bowl G300 SKZ 1 4 Indicator If fitted See product literature 1 5 Filter element G300 series See product datasheet 1 Figure 2 F310 section drawing Note All product data requirements can be found at www pall com Outlet Inlet Bypass valve 3 O ring 1 Head Bowl 2 5 Element Versalon MEDIUM PRESSURE FILTERS F310 EN ...

Page 6: ... plants throughout the world For Pall representatives in your area please go to www pall com contact Because of technological developments related to the products systems and or services described herein the data and procedures are subject to change without notice Please consult your Pall representative or visit www pall com to verify that this information remains valid 25 Harbor Park Drive Port W...