Specifications

Housing materials:

Head:  

SG iron to BSEN1563 or American equivalent

Bowl:   

Aluminium

Bypass Valve  Stainless steel and polyamide

Maximum operating pressure:

70 bar (1,015 psi)

Rated fatigue pressure:

0-40 bar (580 psi) per NFPA T2.6.1 R2-2001 CAT C/90

Proof pressure:

105 bar (1522 psi)

Typical burst pressure:

210 bar minimum (3045 psi)

Element collapse pressure:

G300 element 10 bard (145 psid) differential minimum

Operating temperature range:

-29 °C to 120 °C (-20 °F to 250 °F) with fluorocarbon seals for 

petroleum based and specified synthetic fluids 50 °C (122 °F) 

maximum in HWCF, water-oil emulsion or water glycol

Bypass valve setting options:
3.4 +/- 0.3 bard (50 PSID +/- 5psi) 

4.5 +/- 0.5 bard (65 PSID +/- 7psid)

Seals:

The actual operating conditions should be checked by the  

user to ensure that the  element, housing and all seals are 

compatible with the fluid and application, and are within local 

safety codes. Please contact Pall or an approved distributor if 

further information is required.

Receipt of equipment

The filter housing, and any optional equipment, may be  

packed individually if requested by the customer. Unpack 

carefully and ensure optional items are not mislaid in 

packaging to be discarded.

General sources of information

3.1   For dimensions, operating parameters, assembly/

element part number, ordering information, notes, 

performance data and specifications refer to 

M&EF310EN

3.2    Where under reasonably foreseeable conditions, 

including external fires, the allowable limits could be 

exceeded, suitable protective devices must be installed 

by the customer within the connecting fluid system.

Installation of housing

4.1    The filter can be installed in any attitude, but for ease of 

servicing, it is recommended that it be installed vertically 

with the filter bowl pointing downwards.

4.2    The minimum clearance required for element removal is 

150mm (6”).

4.3    Threaded differential pressure devices, when fitted,  

must be torque tightened up to 38 ft/lb or 54 Nm.  

Visual indicators should be clearly visible when 

assembly is installed.

NOTE: The F310 head is supplied with either an unmachined 

or one machined differential pressure warning port fitted with a 

plastic shipping plug. 

4.4    Mount the filter assembly in position using four  

3/8”-16 UNC 2B (‘A’ ports) or M10 x 1.5 (‘C’ ports)  

bolts in the holes on the head mounting pads. Torque 

bolts to 9-19 ft/lb or 12-26 Nm.

4.5    Use a check valve downstream of the filter if there is a 

possibility of reverse flow.

4.6    Install the filter housing using additional piping/valving  

to allow complete filter assembly bypass if filter 

maintenance is required without system shutdown.  

This series is not available in a duplex or service  

bypass configuration.

NOTE: Piping supports should be provided as close as is 

practicable to the port connections in order to minimize 

external loads. This filter assembly must not be electronically 

isolated from the user’s earthing system. This filter assembly 

must be earthed by connecting the user’s earthing system to 

one of the inlet/outlet connections.

4.7    Connect lines or hoses to housing inlet and outlet ports.
NOTE: A painted filter housing is optional. The coating on the 

filter housing is a suitable painting base. Mask the differential 

pressure warning device and nameplate if fitted for painting.

4.8     Bleed filters. Open plug at top of filter (if fitted) one and a 

half turns. Jog filter and fill filter until all air bleeds through, 

then tighten the plug. Pressurize system fully and check 

for leaks. If leaks occur, refer to paragraph 5.2.      

CAUTION: 
Maximum surge flow should not exceed 1.3 times normal 

flow.

WARNING:

USE FITTINGS OR ADAPTORS COMPATIBLE WITH 

SPECIFIED PORTS SUPPLIED. USE OF INCORRECT 

FITTINGS OR ADAPTORS CAN CAUSE FILTER 

HOUSING FAILURE RESULTING IN LOSS OF 

PRESSURE AND POSSIBLE SYSTEM FAILURE  

OR PERSONAL INJURY.

CAUTION:
Reverse flow through filter element will cause damage.

CAUTION:
Failure to bleed the filter housing adequately will 

increase the dissolved air content of the system fluid 

which will shorten fluid life and may cause other 

problems in the system.

CAUTION:
Never operate the filter unless the warning device port 

is sealed. 

F310

V E r S a l o N   M E D I U M   P r E S S U r E   F I l T E r S

EN

Summary of Contents for Versalon F310 Series

Page 1: ...om pipe work to avoid static discharge It may be necessary to allow time for the static charge to dissipate before removal Internal static discharge within a charged filter capsule may result in damage to the filter media For further information please contact Pall RECEIPT OF EQUIPMENT WARNING PLEASE CHECK THE PRODUCT LABEL PRIOR TO USE TO ENSURE PRODUCT PART NUMBERS CORRESPOND TO THE APPLICATION ...

Page 2: ...ndicators should be clearly visible when assembly is installed NOTE The F310 head is supplied with either an unmachined or one machined differential pressure warning port fitted with a plastic shipping plug 4 4 Mount the filter assembly in position using four 3 8 16 UNC 2B A ports or M10 x 1 5 C ports bolts in the holes on the head mounting pads Torque bolts to 9 19 ft lb or 12 26 Nm 4 5 Use a che...

Page 3: ...evices actuate when the element needs changing or because of high fluid viscosity in cold start conditions 6 2 If visual indicator is fitted and actuates during cold start button changes from white to red it will automatically reset when the normal operating condition is reached If indicator actuates after resetting replace element 6 3 If electrical differential device is fitted the use of both po...

Page 4: ...whatsoever 7 Filter element installation servicing During servicing the external surfaces of the filter assembly must be cleaned to remove any dust deposits Servicing must be conducted using suitable tools that do not present a hazard Servicing must also not be carried out when a potentially explosive atmosphere is present Refer to product data sheet for item numbers for applicable replacement ele...

Page 5: ...ead to bowl G300 SKZ 1 4 Indicator If fitted See product literature 1 5 Filter element G300 series See product datasheet 1 Figure 2 F310 section drawing Note All product data requirements can be found at www pall com Outlet Inlet Bypass valve 3 O ring 1 Head Bowl 2 5 Element Versalon MEDIUM PRESSURE FILTERS F310 EN ...

Page 6: ... plants throughout the world For Pall representatives in your area please go to www pall com contact Because of technological developments related to the products systems and or services described herein the data and procedures are subject to change without notice Please consult your Pall representative or visit www pall com to verify that this information remains valid 25 Harbor Park Drive Port W...

Reviews: