UR619/699

UR619/699 Series

R E T U R N   L I N E   F I LT E R S

s e r v i c e  

i n s t r u c t i o n s

7.6

Lubricate the element O-rings with clean system fluid and
install element over the center post (3) and into its cage (shell)
assembly (4). Reset the visual indicator, if fitted, before refitting
cover. Lightly lubricate cover O-ring with clean system fluid
and refit cover assembly ensuring it engages with the center
post threads. HAND TIGHTEN cover handle until cover
assembly and body assembly are bottomed together. O-ring
sealing is not improved by over tightening. DO NOT USE
PIPE, WRENCH, HAMMER, OR ANY OTHER TOOL TO
TIGHTEN HANDLE!

7.7

Open vent plug (10) on housing and pressurize system. 
This allows clean pressurized fluid to fill the housing and 
bleed off air. 

7.8

Close vent plug on appearance of clear fluid. Check for leaks.

7.9

After element change ENSURE VISUAL DIFFERENTIAL
PRESSURE DEVICE IS RESET BY PUSHING IN THE RED
BUTTON; electrical switches reset automatically. When system
reaches normal operating temperature, check that the
electrical switch has not actuated and/or the visual warning
button has remained depressed. If visual indicator rises due to
a cold start condition, reset again as per section 6

8

Warranty, Limitation of Liability and
Remedies

THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR
ANY PARTICULAR PURPOSE WITH RESPECT TO ANY OF THE
PRODUCTS, NOR IS THERE ANY OTHER WARRANTY EXPRESS OR
IMPLIED, EXCEPT AS PROVIDED FOR HEREIN.
For a period of twelve months from the date of delivery from Seller or
three thousand hours of use, whichever occurs first (the "Warranty
Period", Seller warrants that products manufactured by Seller when
properly installed and maintained, and operated at ratings,
specifications and design conditions, will be free from defects in
material and workmanship. By way of explanation and not limitation,
the Seller does not warrant the service life of the filter element as this
is beyond the Seller's control and depends upon the condition of the
system into which the filter is installed.
Seller's liability under any warranty is limited solely (in Seller's
discretion) to replacing (FOB original ship point), repairing or issuing
credit for products that become defective during the Warranty Period.
Purchaser shall notify Seller promptly in writing of any claims and
provide Seller with an opportunity to inspect and test the product
claimed to be defective. Buyer shall provide Seller with a copy of the
original invoice for the product, and prepay all freight charges to
return any products to Seller's factory, or other facility designated by
Seller. All claims must be accompanied by full particulars, including
system operating conditions, if applicable.
Seller shall not be liable for any product altered outside of the Seller's
factory except by Seller or Seller's authorized distributor, and then, as
to the latter, only for products which have been assembled by the
distributor in accordance with Seller's written instructions. Nor shall
Seller be liable for a product subjected to misuse, abuse, improper
installation, application, operation, maintenance or repair, alteration,
accident or negligence in use, storage transportation or handling.
In no event will Seller be liable for any damages, incidental,
consequential or otherwise, whether arising out of or in connection
with the manufacture, packaging, delivery, storage, use, misuse, or
non use of any of its products or any other cause whatsoever.

4

7

Filter element servicing

During servicing, the external surfaces of the filter assembly must be
cleaned to remove any dust deposits.
Servicing must be conducted using suitable tools that do not present
a hazard.
Servicing must not be carried out when a potentially explosive
atmosphere is present.

Refer to Service Parts List (Section 10) for item numbers for
applicable replacement element series. Remove and replace element
as follows:
7.1

Turn off and depressurize the system. Open vent plug (10) at
top of filter on the cover assembly (5) one and one-half turns.

7.2

Open one or both drain plugs (11) on bottom of filter head and
drain housing. Reinstall and tighten drain plug(s).

7.3

Manually turn filter housing handle counter-clockwise to
remove cover assembly. No tools should be needed or used
to remove the cover assembly.

Note: The UR619/699C series assembly is equipped with an
extraction mechanism within the cover assembly. Turn the cover
handle counterclockwise until handle threads disengage then lift
the cover slightly to pull the element free from its cage. Releasing
the tension on the cover will allow "retraction spring clips"
(located in the cover assembly) to return to their free position.
Cover can now be removed, making the element accessible. 

7.4

Remove filter element (8) and carefully inspect the surface for
visible contamination. Normally no dirt should show, but
visible dirt or particles can be an early warning of system
component breakdown and can indicate potential failure.
Discard both the filter element and its O-ring (6a). The filter
element is NOT CLEANABLE. Any attempt to clean the filter
element can cause degradation of the filter medium and allow
contaminated fluid to pass through the filter element.

7.5

Inspect filter cover assembly (5) for possible damage or
malfunction. Replace any damaged parts. Remove any
accumulated dirt. DO NOT run the system without a filter
element installed. Check that the O-ring on the cover (6b)
assembly is not damaged. Use replacement filter element 
part number called for on assembly nameplate.

WARNING:
FAILURE TO DEPRESSURISE THE FILTER BEFORE
SERVICING ELEMENT COULD RESULT IN
EXPLOSIVE LOSS OF FLUID, DAMAGE TO
EQUIPMENT AND POSSIBLE PERSONAL INJURY.

WARNING:
DO NOT ATTEMPT TO CLEAN OR RE-USE THE
ELEMENT.
ONLY USE GENUINE PALL REPLACEMENT FILTER
ELEMENTS. USE OF SUBSTITUTE ELEMENTS MAY
INVALIDATE PRODUCT WARRANTY.

CAUTION:
Filter elements should be replaced upon indication or
at specified intervals, six months maximum. Failure to
change the element will cause the filter to go on
bypass.

WARNING:
FAILURE TO REPLACE DAMAGED PARTS IN FILTER
CAN CAUSE COMPONENTS IN THE SYSTEM TO
FAIL OR DEGRADE IN THEIR PERFORMANCE.

Summary of Contents for UR619 Series

Page 1: ...UR619 699 UR619 699 Series service instructions 1371630 PME SI UR619 699 EN UR619 699 Service Instructions ENGLISH ...

Page 2: ...ards 4 2 The minimum clearance required for element removal is as follows 4 2 1 443mm or 17 5 for length 20 and 951mm or 37 5 for length 40 assemblies 4 2 2 The UR619 UR699 Housing is supplied without a filter element For element installation and servicing procedures refer to Section 7 4 3 Threaded differential pressure devices when fitted must be torque tightened to 30 33 ft lb or 40 45 Nm All vi...

Page 3: ... depressing the button when the normal operating temperature is reached If indicator actuates after resetting replace element NOTE Option P visual indicator has thermal lockout and manual reset No signal below 0 C 32 F signal above 29 C 80 F 6 3 If the electrical switch actuates e g red light comes on during cold start continue operating until the signal red light goes out as system warms to norma...

Page 4: ...nstructions Nor shall Seller be liable for a product subjected to misuse abuse improper installation application operation maintenance or repair alteration accident or negligence in use storage transportation or handling In no event will Seller be liable for any damages incidental consequential or otherwise whether arising out of or in connection with the manufacture packaging delivery storage use...

Page 5: ...Filter Head 1 2 Tube 1 3 Centre post 1 4 Shell assembly cage 1 5 Cover assembly 1 6a 6b O rings UR619SKZ UR699SKZ 1 Seal Kit fluorocarbon 7 Indicator Blanking plug See product literature 2 8 Filter element UE619 Z 1 See product literature 9 Indicator plug port 1 10 Vent plug 1 11 Bleed drain plugs 2 12 Fill plug 1 13 Mounting bracket kit 1 ...

Page 6: ...UR619 699 UR619 699 Series RETURN LINE FILTERS s e r v i c e instructions 6 2 4 8 7 or 9 3 1 Figure 2 12 7 or 9 6b 6a 13 10 5 11 UR619 Series UR699 Series 1 Not shown on this diagram Inlet ...

Page 7: ... AA 4 fori completamente filettati profondità AA 4 tapgaten met draad over volle diepte 4st fästhål Gänga Z Min gängdjup AA GG Q Flange Connection Details Flange Code Nominal Tube Size GG Q Z Thread AA D24 11 2 1 406 2 750 1 2 13 UNC 1 F24 11 2 35 7 mm 69 8 mm M12 x 1 75 25 mm D32 2 1 688 3 062 1 2 13 UNC 1 F32 2 42 9 mm 77 8 mm M12 x 1 75 25 mm D40 21 2 2 000 3 500 1 2 13 UNC 1 F40 21 2 50 8 mm 8...

Page 8: ... in the USA Copyright 2008 Pall Corporation Visit us on the web at www pall com Pall Corporation has offices and plants throughout the world in locations including Argentina Australia Austria Belgium Brazil Canada China France Germany India Indonesia Ireland Italy Japan Korea Malaysia Mexico the Netherlands New Zealand Norway Poland Puerto Rico Russia Singapore South Africa Spain Sweden Switzerlan...

Reviews: