7.2   Unscrew and remove filter cover/adaptor assembly 

(2) from head (1) counterclockwise when viewed from 

above. It may be necessary to use a 24mm wrench on 

the hexagon on the filter cover assembly (2) to loosen 

the cover initially. Check that the O-rings are not 

damaged. 

7.3   The cover/adaptor assy will pull the elements and  

 

canister from the filter unit. Hold the canister and  

 

adaptor to remove the element from the canister, then  

 

hold the element and adaptor to remove the element  

 

from the adaptor. 

7.4   Dump remaining fluid from canister into a container.  

 

Lubricate the element O-rings with clean system fluid.  

 

Install new element into canister and seat into bottom  

 

of canister. 

7.5   Install adaptor into element. Then install canister/cover  

 

assy into head. Thoroughly clean the cover threads.  

 

Thread cover into head to seal unit. HAND TIGHTEN  

 ONLY.

7.6   Carefully inspect the surface of the removed filter 

element for visible contamination. Normally no dirt 

should show, but visible dirt or particles can be an early 

warning of system component failure. Discard both the 

filter element and its O-rings. The filter element is not 

CLEANABLE. Any attempt to clean the filter element 

can cause degradation of the filter medium and allow 

contaminated fluid to pass through the filter element.

7.7   DO NOT run the system without a filter element installed. 

Use replacement filter element part number called for on 

the element change label.

 7.8  After starting the system check for leaks as per section  

 

5.2. When system reaches normal operating  

 

 

temperature, check that the pressure gauge shows  

 

pressure in the normal operating range.

3

Routine maintenance

5.1   Pall filters do not normally require special attention 

except for periodic monitoring of the pressure gauge. 

We recommend scheduled replacement of filter element 

every six months or sooner, and have ample supply of 

spare elements available. 

5.2   If external leakage is noted, replace O-ring at leak. If 

leakage persists, check sealing surfaces for scratches or 

cracks; replace any defective parts.

5.3   The pressure gauge will indicate when the element 

needs changing or because of high fluid viscosity in 

‘cold start’ conditions. If ‘cold start’ conditions exist,  

see Section 6.2 and 6.3.

5.4   A dirty system can quickly plug a new filter element, 

especially with Pall high efficiency filter media. It may 

require one or two initial element changes to stabilize 

element life. If element life is short or differential 

pressure is excessive, filter may be undersized; refer to 

the sizing and selection section of the product literature 

or contact your local Pall representative.

Pressure gauge

6.1   The pressure gauge will indicate when the element 

needs changing or because of high fluid viscosity in 

‘cold start’ conditions. 

6.2   If a pressure gauge is fitted and shows high pressure 

during ‘cold start’ conditions, check that the pressure 

returns to a ‘normal’ reading when the normal operating 

temperature is reached. If the gauge continues to show 

high pressure after system warm-up, replace the filter 

element.

ENGLISH

T200

T200 Series

RETURN LINE IN-TANK FILTERS

s e r v i c e  

i n s t r u c t i o n s

Filter element servicing

During servicing, the external surfaces of the filter assembly 

must be cleaned to remove any dirt.

Servicing must be conducted using suitable tools that do not 

present a hazard.

Servicing must not be carried out when a potentially explosive 

atmosphere is present.

Refer to Service Parts List (Section 9) for item numbers for 

applicable replacement element series. Remove and replace 

element as follows:

7.1   Turn off and depressurize the system.

WARNING:

FAILURE TO DEPRESSURISE THE FILTER 

BEFORE SERVICING ELEMENT COULD RESULT 

IN EXPLOSIVE LOSS OF FLUID, DAMAGE TO 

EQUIPMENT AND POSSIBLE PERSONAL INJURY.

WARNING:

DO NOT ATTEMPT TO CLEAN OR RE-USE THE 

ELEMENT.

ONLY USE GENUINE PALL REPLACEMENT FILTER 

ELEMENTS. USE OF SUBSTITUTE ELEMENTS MAY 

INVALIDATE PRODUCT WARRANTY.

CAUTION:

Filter elements should be replaced upon high 

differential pressure or at specified intervals, six 

months maximum is recommended. Failure to change 

the element will cause the filter to go on bypass.

Summary of Contents for T200 Series

Page 1: ...y to allow time for the static charge to dissipate before removal Internal static discharge within a charged filter capsule may result in damage to the filter media For further information please contact Pall RECEIPT OF EQUIPMENT WARNING PLEASE CHECK THE PRODUCT LABEL PRIOR TO USE TO ENSURE PRODUCT PART NUMBERS CORRESPOND TO THE APPLICATION a Unpack carefully and check items against invoice b Stor...

Page 2: ...s the allowable limits could be exceeded suitable protective devices must be installed by the customer within the connecting fluid system 4 Installation of housing 4 1 The filter should be installed vertically with the cover pointing upwards 4 2 The minimum clearance required for element removal of is as follows 248mm 9 8in for length 8 147mm 5 8in for length 4 4 3 Threaded pressure gauges pipe pl...

Page 3: ...rsists check sealing surfaces for scratches or cracks replace any defective parts 5 3 The pressure gauge will indicate when the element needs changing or because of high fluid viscosity in cold start conditions If cold start conditions exist see Section 6 2 and 6 3 5 4 A dirty system can quickly plug a new filter element especially with Pall high efficiency filter media It may require one or two i...

Page 4: ...ucts that become defective during the Warranty Period Purchaser shall notify Seller promptly in writing of any claims and provide Seller with an opportunity to inspect and test the product claimed to be defective Buyer shall provide Seller with a copy of the original invoice for the product and prepay all freight charges to return any products to Seller s factory or other facility designated by Se...

Page 5: ...r to head 1 7 O ring head to tank 1 8 Spring 1 9 Filter element HCT200 series 1 10 Bypass valve 1 Spare Parts List Seal Kit P N ST 200 SKH Items 6 7 Cover Kit P N ST 200 CVRHB Items 2 3 6 8 10 Element P N HCT 200 FCS 4H 4 CS Media Element P N HCT 200 FCS 8H 8 CS Media Element P N HCT 200 FCT 4H 4 CT Media Element P N HCT 200 FCT 8H 8 CT Media Canister Kit P N ST 200 CANR 4 Canister Kit P N ST 200 ...

Page 6: ...6 2 6 Figure 2 T200 T200 Series RETURN LINE IN TANK FILTERS service instructions 3 10 4 8 1 7 9 ...

Page 7: ...7 T200 T200 Series RETURN LINE IN TANK FILTERS service instructions Tank mounting dimensions ...

Page 8: ...e world For Pall representatives in your area please go to www pall com contact Because of technological developments related to the products systems and or services described herein the data and procedures are subject to change without notice Please consult your Pall representative or visit www pall com to verify that this information remains valid Copyright 2018 Pall Corporation Athalon Pall and...