2
1 Specifications
Housing materials:
Head: Aluminium Alloy
Canister: Polymide PA66
Maximum operating pressure:
10 bar (150 psi)
Element collapse pressure:
HCT200 series element 10 bard (150 psid) differential minimum
Operating temperature range:
-43°C to 100°C (-45°F to 212°F) with nitrile seals for petroleum
based and specified synthetic fluids, 60°C (140°F) max HWCF
or water glycol fluids
Bypass valve setting options:
3.4 ± 0.3 bard (50 ± 5 psid) cracking pressure
Seals:
Nitrile
The actual operating conditions should be checked by the
user to ensure that the element, housing and all seals are
compatible with the fluid and application, and are within local
safety codes. Please contact Pall or an approved distributor if
further information is required.
2
Receipt of equipment
The filter housing, and any optional equipment, are packed
individually for assembly by the customer. Unpack carefully
and ensure optional items are not mislaid in packaging to be
discarded.
3
General sources of information
3.1 For dimensions, operating parameters, assembly/
element part number, ordering information, notes,
performance data and specifications refer to datasheet.
3.2 This equipment has been assessed in accordance with
the guidelines laid down in the European Pressure
Directive 97/23/EC and has been classified within sound
engineering practice S.E.P. We hereby declare the
equipment meets the requirements of article 3, section
3, thus meeting the directive requirements. Under the
provisions of this directive the filter assembly is suitable
for use with group 2 fluids only.
3.3 Where under reasonably foreseeable conditions,
including external fires, the allowable limits could be
exceeded, suitable protective devices must be installed
by the customer within the connecting fluid system.
4
Installation of housing
4.1 The filter should be installed vertically with the cover
pointing upwards.
4.2 The minimum clearance required for element removal of
is as follows:
248mm (9.8in) for length 8, 147mm (5.8in) for length 4.
4.3 Threaded pressure gauges, pipe plug or elbow, when
fitted, hand tighten plus 1-2 turns with a wrench.
NOTE: The housing is supplied with a machined pressure
gauge port (position 1) fitted with a pressure gauge.
4.4 Mount the filter assembly in position using 2 or 4 bolts
in the holes on the head mounting pads. Torque bolts to
16-20 lbft (22-27 Nm). When using a 2 position mounting
stud, the maximum height of the stud should be 24mm.
4.5 Install the filter housing using additional piping/valving to
allow complete filter assembly bypass if filter maintenance
is required without system shutdown. This series is not
available in a duplex or service bypass configuration.
4.6 Connect lines or hoses to housing inlet ports.
Note: Painting of the filter housing is optional. The coating
on the filter housing is a suitable painting base. Cover the
pressure warning device if painting of the housing takes place.
CAUTION:
Maximum surge flow should not exceed 1.3 times
normal flow.
WARNING:
USE FITTINGS OR ADAPTORS COMPATIBLE WITH
PORTS SUPPLIED AS SHOWN BY PART NUMBER
ON NAMEPLATE AND NOTED IN DATA SHEETS:
USE OF INCORRECT FITTINGS OR ADAPTORS CAN
CAUSE FILTER HOUSING OR MANIFOLD FAILURE
RESULTING IN LOSS OF PRESSURE AND POSSIBLE
SYSTEM FAILURE OR PERSONAL INJURY.
CAUTION:
Reverse flow through filter element will cause damage.
CAUTION:
Never operate the filter unless all warning device ports
are sealed.
T200
T200 Series
RETURN LINE IN-TANK FILTERS
s e r v i c e
i n s t r u c t i o n s