1 Specifications

Housing materials:

Head: Aluminium Alloy 

Canister: Polymide PA66

Maximum operating pressure:

10 bar (150 psi)

Element collapse pressure:

HCT200 series element 10 bard (150 psid) differential minimum

Operating temperature range:

-43°C to 100°C (-45°F to 212°F) with nitrile seals for petroleum 

based and specified synthetic fluids, 60°C (140°F) max HWCF 

or water glycol fluids

Bypass valve setting options:

3.4 ± 0.3 bard (50 ± 5 psid) cracking pressure

Seals:

Nitrile

The actual operating conditions should be checked by the 

user to ensure that the element, housing and all seals are 

compatible with the fluid and application, and are within local 

safety codes. Please contact Pall or an approved distributor if 

further information is required.

Receipt of equipment

The filter housing, and any optional equipment, are packed 

individually for assembly by the customer. Unpack carefully 

and ensure optional items are not mislaid in packaging to be 

discarded.

General sources of information

3.1   For dimensions, operating parameters, assembly/

element part number, ordering information, notes, 

performance data and specifications refer to datasheet.

3.2   This equipment has been assessed in accordance with 

the guidelines laid down in the European Pressure 

Directive 97/23/EC and has been classified within sound 

engineering practice S.E.P. We hereby declare the 

equipment meets the requirements of article 3, section 

3, thus meeting the directive requirements. Under the 

provisions of this directive the filter assembly is suitable 

for use with group 2 fluids only.

3.3   Where under reasonably foreseeable conditions, 

including external fires, the allowable limits could be 

exceeded, suitable protective devices must be installed 

by the customer within the connecting fluid system.

Installation of housing

4.1   The filter should be installed vertically with the cover 

pointing upwards.

4.2   The minimum clearance required for element removal of 

is as follows: 

 

248mm (9.8in) for length 8, 147mm (5.8in) for length 4.

4.3   Threaded pressure gauges, pipe plug or elbow, when 

fitted, hand tighten plus 1-2 turns with a wrench. 

NOTE: The housing is supplied with a machined pressure 

gauge port (position 1) fitted with a pressure gauge.

4.4   Mount the filter assembly in position using 2 or 4 bolts 

in the holes on the head mounting pads. Torque bolts to 

16-20 lbft (22-27 Nm). When using a 2 position mounting 

stud, the maximum height of the stud should be 24mm.

4.5   Install the filter housing using additional piping/valving to 

allow complete filter assembly bypass if filter maintenance 

is required without system shutdown. This series is not 

available in a duplex or service bypass configuration.

4.6   Connect lines or hoses to housing inlet ports.
Note: Painting of the filter housing is optional. The coating 

on the filter housing is a suitable painting base. Cover the 

pressure warning device if painting of the housing takes place.

CAUTION: 

Maximum surge flow should not exceed 1.3 times 

normal flow.

WARNING:

USE FITTINGS OR ADAPTORS COMPATIBLE WITH 

PORTS SUPPLIED AS SHOWN BY PART NUMBER 

ON NAMEPLATE AND NOTED IN DATA SHEETS: 

USE OF INCORRECT FITTINGS OR ADAPTORS CAN 

CAUSE FILTER HOUSING OR MANIFOLD FAILURE 

RESULTING IN LOSS OF PRESSURE AND POSSIBLE 

SYSTEM FAILURE OR PERSONAL INJURY.

CAUTION:

Reverse flow through filter element will cause damage.

CAUTION:

Never operate the filter unless all warning device ports 

are sealed. 

T200

T200 Series

RETURN LINE IN-TANK FILTERS

s e r v i c e  

i n s t r u c t i o n s

Summary of Contents for T200 Series

Page 1: ...y to allow time for the static charge to dissipate before removal Internal static discharge within a charged filter capsule may result in damage to the filter media For further information please contact Pall RECEIPT OF EQUIPMENT WARNING PLEASE CHECK THE PRODUCT LABEL PRIOR TO USE TO ENSURE PRODUCT PART NUMBERS CORRESPOND TO THE APPLICATION a Unpack carefully and check items against invoice b Stor...

Page 2: ...s the allowable limits could be exceeded suitable protective devices must be installed by the customer within the connecting fluid system 4 Installation of housing 4 1 The filter should be installed vertically with the cover pointing upwards 4 2 The minimum clearance required for element removal of is as follows 248mm 9 8in for length 8 147mm 5 8in for length 4 4 3 Threaded pressure gauges pipe pl...

Page 3: ...rsists check sealing surfaces for scratches or cracks replace any defective parts 5 3 The pressure gauge will indicate when the element needs changing or because of high fluid viscosity in cold start conditions If cold start conditions exist see Section 6 2 and 6 3 5 4 A dirty system can quickly plug a new filter element especially with Pall high efficiency filter media It may require one or two i...

Page 4: ...ucts that become defective during the Warranty Period Purchaser shall notify Seller promptly in writing of any claims and provide Seller with an opportunity to inspect and test the product claimed to be defective Buyer shall provide Seller with a copy of the original invoice for the product and prepay all freight charges to return any products to Seller s factory or other facility designated by Se...

Page 5: ...r to head 1 7 O ring head to tank 1 8 Spring 1 9 Filter element HCT200 series 1 10 Bypass valve 1 Spare Parts List Seal Kit P N ST 200 SKH Items 6 7 Cover Kit P N ST 200 CVRHB Items 2 3 6 8 10 Element P N HCT 200 FCS 4H 4 CS Media Element P N HCT 200 FCS 8H 8 CS Media Element P N HCT 200 FCT 4H 4 CT Media Element P N HCT 200 FCT 8H 8 CT Media Canister Kit P N ST 200 CANR 4 Canister Kit P N ST 200 ...

Page 6: ...6 2 6 Figure 2 T200 T200 Series RETURN LINE IN TANK FILTERS service instructions 3 10 4 8 1 7 9 ...

Page 7: ...7 T200 T200 Series RETURN LINE IN TANK FILTERS service instructions Tank mounting dimensions ...

Page 8: ...e world For Pall representatives in your area please go to www pall com contact Because of technological developments related to the products systems and or services described herein the data and procedures are subject to change without notice Please consult your Pall representative or visit www pall com to verify that this information remains valid Copyright 2018 Pall Corporation Athalon Pall and...

Reviews: