7. Are there any damages on mechanical or electrical parts (such as damaged cables)?
10.1.2
Activate Emergency Mode
When Emergency mode is activated, the liftgate sensors are bypassed and can help detect if the liftgate is
not operating due to the sensor or something other than the sensors. To activate Emergency Mode Press
and hold the Open and Lower buttons simultaneo
usly for approximately 10 seconds. An “E” on the control
board will indicate when the liftgate is in Emergency Mode. To unactivate Emergency Mode, power the
liftgate OFF and ON.
10.1.3
Cab Switch L.E.D.s are on but all functions are dead
Possible malfunctions:
1. Short in hand held remote or its wire
remove plug J-31.
2. Short in push button switches wire
remove plug J-30.
After disconnecting plugs
– reboot board by unplugging J-1 for 5 seconds and plug it back.
10.1.4
L.E.D.s continue to stay on, after switch is turned off
Make sure platform is closed and stored vertically.
Adjust the B-16 switch.
Follow this instruction if B-16 IS NOT working:
a) Unplug J-3(w/l and f/c), J-41(B-13, B16) and J-31(Hand control),
jump J-11 #4 to J-41 #GN
Keep the 3 connectors unplugged (gate will operate without plugs connected, loose auto tilt).
b) Unplug J-1 (Main power), wait 10 seconds and plug J-1 back to the board (Reset the board).
c) Plug each connector back, one at a time and check functions of gate after plugging in each.