ILU 40/50 Owner
’s Manual
Revision 1.5
25
6.2
Electrical and Hydraulic Schematic
6.2.1
Wiring Diagram - Truck
2GA. Liftgate
Power Cable
Main
Batteries
(Truck)
*In-Line
Fuse
Wires #2 and #4
go to postitive (+)
4-Conductor Control
Power Cable
from Control Board
Ground
Wires #1 and Gr/Yl
go to ground (-)
Control Board
Location (Inside)
**Resetable
Circuit
Breaker
*In-Line ATC Fuse: 20 Amp.
Replace with same amperage fuse when necessary.
**Resettable Circuit Breaker: 150 Amp Min.
Replace with same amperage breaker when necessary.
NOTICE: DO NOT attempt to jump in-line fuses with other objects other than the specified fuse.
Do not increase the amperage rating of fuse. Serious harm to the liftgate will result when
standard practices are not followed.
Figure 8: Main Wiring for Truck