ILU 40/50 Owner
’s Manual
Revision 1.5
23
5. Is the connection to ground in power pack OK?
Is the ground connection from the tail lift to vehicle OK?
6. Check the oil level in the power pack reservoir.
7. Are there any damages on mechanical or electrical parts (such as damaged cables)?
6.1.2
ON-OFF switch on, but all functions are dead
Possible malfunctions:
1. Short in hand held remote or its wire
unplug Hand-Control.
2. Short in control box wire
remove plug J-30.
After disconnecting plugs
– reboot board by unplugging J-1 for 5 seconds and plug it back.
Open this cap to check the fuses
Replace fuse when
metal bridge is broken