004776370 - 31/01/2019 - PALAZZETTI - PN - ITALY
27
ENGLISH
5.6 ELECTROVENTILATOR
CONNECTIONS
The air fan (V) (Fig. 5.5.1) is located in the rear part
of the stove connected to the flexible pipes A + B.
One suction side of the air fan is already connected
and sealed to the grill (A) on the lower side of the
stove (Fig. 5.5.2).
Connect the other flexible hose (B) (Fig. 5.5.1) to
the grid to be made in the left side (B1) or front (B2)
cladding (Fig. 5.5.3). The hose is already connected
with clamps to the fan must be sealed with silicone
and fixed to the grid with the ties supplied.
The air intake circuit to the heating fan must be
perfectly sealed so as not to interfere with the
combustion air intake circuit.
If the suction circuit is not perfectly sealed, when
the fan is switched on it causes a strong depression
with the possibility of recalling smoke from the
combustion chamber and introducing it into the
hot air supply circuit with the possibility of smoke
escaping from the outlets.
Create an air passage area sufficient for the air
intake of the reheating fan, or use an optional door
kit (P) (Fig. 5.5.2).
A
P
G
A
B
V
B1
B2
B1
A
B2
A
fig. 5.5.2
A
B
fig. 5.5.3
fig. 5.5.1