5.13 INITIAL CONFIGURATION
Depending on the type of installation, the best configuration needs to be selected for the stove operation.
Before proceeding, power up the stove using the main switch (fig. 5.9).
a) Use the arrow buttons to go to the setup menu and then press ;
b) Use the button to select the password “7” and then press
to confirm;
c) Use the buttons to scroll to and select submenu
[30]
; “
--0
” will flash on the display;
d) Press and enter the value “54” using the buttons;
e) Press
to confirm;
f)
The current configuration will be displayed;
g)
To change the configuration, press and enter the value of the new configuration using the
buttons;
h) Press
to confirm.
After having changed the configuration a communication error message may be displayed for a few
seconds. Ignore this and switch the stove off using the safety switch, wait a few seconds and switch it
back on.
TWO DIFFERENT CONFIGURATIONS ARE AVAILABLE:
CONFIGURATION 1 (default)
Set this configuration to switch the stove on or off manually or in programmed mode.
The stove will module its power according to the room temperature read by the probe on the stove.
It is possible to set the function “Eco-mode” to allow the stove switch on or off according to the set
temperature.
In this configuration it is possible to set also the antifreeze function.
CONFIGURATION 2
Set this configuration when the stove is controlled by an external thermostat (or timer thermostat).
In this configuration the stove switches off when reaching the external thermostat setting.
In this configuration it is not possible to set also the antifreeze function.