D
6.4
PRACTICAL ADVICE FOR THE HEATING SYSTEM
• All the connections should be hermetically sealed
and blocked.
• Before starting the appliance, the system should be
tested with an operating pressure of 2.4 bar.
• Before starting the system, clean it by draining all
the water in the system at least once.
• In installations where the heater-cooker alone is
featured, an 18 litre expansion tank can be used (no
smaller than 12 litres) connected to the return line,
near the boiler. On-off valves should not be fitted
between the expansion tank and the boiler!
6.3.4) installiert, so müssen sie nicht getrennt in der
Anlage installiert werden. Das Thermometer (Bauteil
17) zeigt die Wassertemperatur im Kessel
(Betriebstemperatur von 40° bis 85° C).
Der Manometer (Bauteil 16) zeigt der Wasserdruck im
Kessel in Bar.
Unter normalen Betriebsbedingungen beträgt der
einzustellende Druck etwa 1 Bar.
6.4 PRAKTISCHE RATSCHLÄGE FÜR DAS
HEIZSYSTEM
• Alle Anschlüsse müssen hermetisch abgedichtet und
verriegelt werden.
• Vor der Inbetriebnahme des Herdes muss die Anlage
mit einem Betriebsdruck von 2.4 Bar getestet werden.
• Vor Inbetriebnahme der Anlage ist es angezeigt,
dieselbe durch mindestens einmaliges
Ablaufenlassen des Wassers zu reinigen.
• In Installationen, in denen nur der Heizherd vorhanden
ist, kann man ein Expansionsgefäß von 18 Litern (nicht
kleiner als 12 Liter) benutzen, das in Kesselnähe an
der Rücklaufleitung angeschlossen ist. Zwischen
dem Expansionsgefäß und dem Kessel dürfen sich
keine Sperrventile befinden!