21
Palax D270 Active
Translation
1-2017
3.4.
Electric drive, start and emergency stop
The power output of the motor is 4 kW and
the speed is 1,500 r.p.m.
All the electric installations have been made
ready.
The cross-section of the extension cable
required for a tension of 400 V must be at
least 2.5 mm
2
.
The IP class of the machine is 55.
The machine may only be connected to a
power supply equipped with a fault current
switch of 30 mA.
The machine requires a 5-pole extension
cable (L1, L2, L3, N and PE) to operate.
To start the machine, press the green start
button on the starter box, Fig. 3.1 A.
To stop the machine, press the red stop
button on the starter box, Fig. 3.1 B.
The Palax Active is equipped with a plug that
enables switching of the phase, Fig. 3.2 A.
This feature enables changing the direction of rotation of the
electric motor if the motor is running in the wrong direction.
NOTE ! Check the direction of rotation of the engine (in
the SM model).
NOTE ! Electric work may only be carried out by a
professional person.
3.1
B
A