14
Filter Removal and Installation
4. Set filter frame on guide and slowly slide assembly
into collector until the bottom edge of the filter bags
contact ths shaker bar.
Note: Insertion must be in-line with the frame guide.
Inserting at an angle could potentially tear the
tubesheet seal.
5. Insert bag pockets into the shaker bar slots.
6. Push the filter assembly the remaining distance into
the collector and check that all pockets are firmly
seated in the shaker bar.
7. Lift retention handles (for UMA 40 model size, tighten
wing nuts).
8. Replace or close the filter access door and secure.
9. Return power to the collector and resume operation.
filter insert
filter frame
filter bag
UMA-H 250
insert edging
(bottom edging not shown)
UMA 40
wing nuts
(UMA 40 models only)
shaker bar
frame guide
handle