8)
Folding Unit Drum (New type)
8.1)
Fully Extend the Folding Unit on its rails
8.2)
Unlock the Folding Drum Assembly
8.3)
Rotate the Folding Drum all the open
8.4)
By moving the release catch towards the
left (direction of arrow) as shown in the
picture on the right. The Drum should
release from its housing. Use both hands
to support the Drum.
8.5)
To refit the drum, offer the left side up
to its bracket first.
9)
Checking of Folding Drum Position
9.1)
There are 4 studs locating the Drum into
its final position when housed within the
machine. If the machine has been in the
field more than 12 months it is a good
idea to check these to see if they have
become loose.