PairGain 150-1217-03 Manual Download Page 11

Section 150-611-103

Revision 01

Page 11

TABLE 2.  SYSTEM OPTION SETTINGS (CONTINUED)

MODE

CHOICE

DESCRIPTION

“LNCD”

B8ZS

Places both the HLU-611 & HRU-612 into their B8ZS modes.

AMI*

Places both the HLU-611 & HRU-612 into their AMI modes.

“FRMG”

AUTO*

Configures the HiGain system to operate in an auto-framing (AUTO) mode in
which it continuously searches the input T1 bit stream for a valid SF or ESF
frame pattern.  This feature is required for fractional T1 applications (DS0
blocking) where it insures proper channel time slot alignment.  While the HiGain
system can also process unframed data in this AUTO mode, it is recommended
that the unframed (UNFR) mode be used for all unframed applications.  Using
the AUTO mode for unframed applications runs the risk of detecting "pseudo-
valid” frame sequences, which can affect the data integrity.

UNFR

Configures the HiGain system to operate in an unframed mode.  This mode
disables the auto framing process and forces the HiGain system to function as a
transparent bit pipe.

HAIS

DIS*

Prevents a margin alarm from generating an AIS pattern at either TI interface.
Causes the HiGain system to transmit the AIS signal at both the HLU-611 &
HRU-612 T1 output ports when both of the HDSL loops are not in sync
(LOSW).

1LP

Enables a margin alarm to initiate an AIS condition at each T1 output.  Causes
the HiGain system to transmit the AIS signal at both the HLU-611 & HRU-612
T1 output ports when either of the two HDSL loops is not in sync (LOSW) or if a
MARgin alarm occurs.

SAIS

ENA*

Causes the HRU-612 to transmit the AIS signal towards the Network Interface
(NI) when in NREM or Smart-Jack loopback.

DIS

Causes the HRU-612 to transmit the signal from the network towards the NI and
opens and terminates the HRU-612 RCV NI port when an HRU NREM or
Smart-Jack loopback is executed.  The AIS signal is off.

CONF

YES

Confirms that all eleven (listed above) operating modes are to be updated to
their current choices.

NO*

Prevents the most recently selected operating mode choices form being
updated.  They remain as they were before the system option settings
procedure was entered.

MARgin Alrm

Trsh

0 to 15 dB

The Margin Alarm Threshold can only be set via the RS-232 maintenance port.
It determines the minimum allowable margin below which a minor alarm can
occur.

4 dB*

(Default value)

DS0

BLK

The DS0 blocking option can only be set via the RS-232 maintenance port with
a  terminal.  The 4-Character HLU-611 front panel only displays the status of
the blocking option.  BLK indicates at least one channel is blocked.

NONE*

NONE indicates no channels are blocked.

“xxxx”

Panel Set

Only these options can be set by the front panel.  All of the options can only be
set from the RS-232 maintenance port.

*Indicates HLU-611 factory settings.  HiGain can be set to these default settings by pressing the SEL button for
6 seconds and then selecting the YES response to the resulting DFLT message.

Summary of Contents for 150-1217-03

Page 1: ...S 2 2 APPLICATIONS 2 3 SPECIFICATIONS 3 4 CERTIFICATION 4 5 WARRANTY 4 6 TECHNICAL ASSISTANCE 4 B FUNCTIONAL DESCRIPTION 4 7 FUNCTIONAL OPERATION 4 8 OPTIONS 7 8 9 LOOPBACKS 8 9 C INSTALLATION AND TES...

Page 2: ...Circuit ID option 2 APPLICATIONS 2 01 HiGain 2 provides a cost effective easy to deploy method for delivering T1 high Capacity Digital Service HCDS over 1 metallic pair The fiber like quality service...

Page 3: ...watts max Heat Dissipation 6 watts typ 8 watts max Fusing Internal connected to FUSEALARM output on pin 32 Span Voltage 170 Vdc max Margin Indicator Displays span SNR margin for both spans relative t...

Page 4: ...klin Avenue Tustin CA 92680 ATTN Repair and Return Dept 714 832 9922 800 638 0031 6 TECHNICAL ASSISTANCE 6 01 PairGain Technical Assistance is available 24 hours a day 7 days a week by contacting Pair...

Page 5: ...ction with the FIFO regulates the output bit rate and reconstructs the DS1 clock at the exact rate received from the remote end The HiGain 2 system operates at DS1 rates of 1 544 Mbs with up to 200 bi...

Page 6: ...termines the shelf fusing requirements HLU 611 shelves are normally fused at 10 amps A fully loaded shelf of 13 HLU 611s draws 4 9 amps in the worst case This is well within the 10 amp fuse limit 7 16...

Page 7: ...tes and the normal margin displays reappear If this time out occurs with an active loopback in effect the appropriate loopback message appears in addition to the loop margin messages Once the manual l...

Page 8: ...selection The DS0 channels are blocked or unblocked by entering each channel s number Multiple channels can be selected by inserting a space between each entry After all the new settings have been ma...

Page 9: ...in 7 or 4 in 7 in band codes to loop up the HRU NREM or CLOC respectively NLOC NREM are issued from the HLU DS1 interface CLOC CREM are issued from the HRU DS1 interface All looped states are termina...

Page 10: ...ter in band loopback codes PWRF DIS Disables powering to the HRU 612 ENA Enables powering to the HRU 612 ZBTS ON Tells the HiGain system that the ESF frame is operating in its Zero Byte Time Slot Inte...

Page 11: ...nsmit the AIS signal at both the HLU 611 HRU 612 T1 output ports when either of the two HDSL loops is not in sync LOSW or if a MARgin alarm occurs SAIS ENA Causes the HRU 612 to transmit the AIS signa...

Page 12: ...on Note 910 Part 325 910 100 for more SPLB details 9 07 When T1 loopback tests are performed on the HiGain 2 system with metallic loopback connections at either end the DS1 code that exists at the met...

Page 13: ...when power is initially applied to the 611 In order to conserve power it only remains on for 5 minutes if neither the MODE nor SEL buttons are depressed The use of either button restarts the 5 minute...

Page 14: ...to normal 4 Have the C O tester send the HLU 4 in 7 in band loop up for 5 seconds Observe that the HLU displays the NLOC message indicating an HLU loopback is in effect 5 Repeat step 2 If the test pas...

Page 15: ...e returned pattern 20 errors if ILR 2 were sent followed by normal looped data Note that this error pattern will repeat every 20 seconds as long as the IOR loopback pattern is being sent This same 20...

Page 16: ...1101 D 0101 5 1110 E 1010 A TIME OUT OVERRIDE Loopback Time out Override 1101 D 0101 5 1101 D 0110 6 FAR END NIU ACTIVATE Unblock AIS pass 2 in 5 1100 C 0101 5 0101 5 0100 4 IOR POWER DOWN HLU Remove...

Page 17: ...e returned pattern 20 errors if ILR 2 were sent followed by normal looped data Note that this error pattern will repeat every 20 seconds as long as the IOR loopback pattern is being sent This same 20...

Page 18: ...1101 D 0101 5 1110 E 1010 A TIME OUT OVERRIDE Loopback Time out Override 1101 D 0101 5 1101 D 0110 6 FAR END NIU ACTIVATE Unblock AIS pass 2 in 5 1100 C 0101 5 0101 5 0100 4 IOR POWER DOWN HLU Remove...

Page 19: ...he codes required to execute all the HiGain 2 loopbacks shown in Figure 5 Note that all code sequences must be present for at least 5 seconds LU LOOPUP LD LOOPDOWN NI NETWORK INTERFACE CI CUSTOMER INT...

Page 20: ...owing list summarizes the codes required to execute all the HiGain 2 loopbacks shown in Figure 5 Note that all code sequences must be present for at least 5 seconds LU LOOPUP LD LOOPDOWN NI NETWORK IN...

Page 21: ...followed by 5 seconds of returning data pattern followed by 231 logic errors including the frame bits occur in the returned pattern 20 errors if ILR 2 were sent followed by normal looped data Note th...

Page 22: ...QUERY LPBK Alternate Query loopback 1101 D 0101 5 1110 E 1010 A TIME OUT OVERRIDE Loopback Time out Override 1101 D 0101 5 1101 D 0110 6 IOR POWER DOWN HLU Removes VHDSL line power 0110 6 0111 7 0110...

Page 23: ...ming bit error occurred at HLU T1 input LBPV Local Bipolar Violation A bipolar violation has been received at the T1 input to the HLU 611 SIG Signal The HLU HRU transceivers are trying to establish co...

Page 24: ...n being received from the DSX 1 Displayed during System Settings mode defined above CODE Line Code AMI B8ZS This is the line code that the HLU is set to receive and transmit at its DSX 1 interface Dis...

Page 25: ...Section 150 611 103 Revision 01 Page 25 Figure 6 HLU 611 Maintenance Menu Main Menu Figure 7 HLU 611 View Span Status Display...

Page 26: ...Section 150 611 103 Revision 01 Page 26 Figure 8 HLU 611 System Settings Menu Figure 9 HLU 611 Set Clock Menu...

Page 27: ...Section 150 611 103 Revision 01 Page 27 Figure 10 HLU 611 View Performance Data Display Figure 11 HLU 611 View Performance History Display...

Page 28: ...1 Page 28 Figure 12 HLU 611 View Alarm History Display Figure 13 HLU 611 Loopback Menu Copyright 1995 PairGain Technologies Inc PairGain is a registered trademark CopperOptics and HiGain are trademark...