TABLE 2. SYSTEM OPTION SETTINGS
MODE
CHOICE
DESCRIPTION
“EQL”
EXT*
Replaces the internal equalizer with a 12 Vpk-pk drive source for an external
equalizer.
0
Sets the Equalizer to DSX-1 for 0-133 feet.
133
Sets the Equalizer to DSX-1 for 133-266 feet.
266
Sets the Equalizer to DSX-1 for 266-399 feet.
399
Sets the Equalizer to DSX-1 for 399-533 feet.
533
Sets the Equalizer to DSX-1 for 533-655 feet.
LBPK
DIS
Configures the HiGain system to ignore all in-band Smart-Jack loopback
commands.
ENA*
Enables the HiGain system to recognize all in-band Smart-Jack loopback
commands.
SPLB
GNLB
Configures the HiGain system to respond to the generic (3/4 in 7) in-band
loopback codes.
A1LB &
A2LB*
Configures the HiGain system to respond to the Teltrend addressable repeater
in-band loopback codes.
A3LB
Configures the HiGain system to respond to the Wescom addressable repeater
in-band loopback codes.
A4LB
Configures the HiGain system to respond to the Wescom Mod 1 addressable
repeater in-band loopback codes.
A5LB
Configures the HiGain system to respond to the Teltrend Mod 1 addressable
repeater in-band loopback codes.
PWRF
DIS
Disables powering to the HRU-612.
ENA*
Enables powering to the HRU-612.
ZBTS
ON
Tells the HiGain system that the ESF frame is operating in its Zero Byte Time
Slot Interface (ZBTSI) mode.
OFF*
Tells the HiGain system that the ESF frame is operating in its normal non-
ZBTSI mode.
ESAL
17
Creates a minor alarm condition which flashes the red STATUS LED when 17
Errored Seconds (ES) (17 HDSL CRC errors on either HDSL loop or a total of
17 BPV and FERR occur within a 24-hour period.
170
Creates a minor alarm condition which flashes the red STATUS LED when 170
ES (170 HDSL cyclic redundancy check (CRC) errors on either HDSL loop or a
total of 170 BPV and FERR) occur within a 24-hour period.
NONE*
Prevents generation of a minor alarm due to excessive Errored Seconds.
“LBTO”
NONE
Disables automatic time-out cancellation of all loopbacks.
20
Sets automatic cancellation of all loopbacks to 20 minutes after initiation.
60
Sets automatic cancellation of all loopback to 60 minutes after initiation.
120*
Sets automatic cancellation of all loopback to 120 minutes after initiation.
ALM
DIS*
Opens the Alarm relay contacts if closed, and prevents another relay alarm
closure from occuring.
ENA
Enables activation of the minor alarm relay when a minor alarm condition
occurs.
Table continued on next page