Table 1 Compliance class

Emissions 
Test

Compliance

Electromagnetic Environment and 
Guidance

RF emissions 
CISPR 11

Group 1

The equipment uses RF energy only for its 
internal function. 
Therefore, its RF emissions are very low and 
are not likely to cause any interference in 
nearby electronic equipment.

RF emissions 
CISPR 11

Class B

Harmonic 
emissions 
IEC 61000-3-2

Class A

Voltage 
fluctuations/ 
flicker 
emissions 
IEC 61000-3-3

Complies

The equipment is suitable for use in all 
establishments, including domestic 
establishments and those directly connected 
to the public low-voltage power supply 
network that supplies buildings used for 
domestic purposes.

Table 2- Compliance standards

Phenomenon

Basic 
Standard of 

Immunity Test 

Level of 

±8 KV contact

±2 KV, ±4 KV, 

±8 KV,±15KV air

±8 KV contact

± 2 K V, ± 4 K V, 

± 8 KV, ±15KV air

3V/m

80 MHz-2.7 GHz

80% AM at 1 KHz

3V/m

80 MHz-2.7 GHz

80% AM at 1 KHz

See table

See table

±1 KV

100 KHz repetition

frequency  

±1 KV

100 KHz repetition

frequency 

Electrostatic 

discharge

IEC 61000-4-2

Radiated RF 

EM fields1

IEC 61000-4-3

Proximity 

fields from RF 

wireless 

communication 

equipment

IEC 61000-4-3

Electrical 

Fast/Transients 

bursts

IEC 61000-4-4

3V

0.15 MHz-80 MHz

6 Vm in ISM bands 

between 0 .15 MHz 

and 80 MHz

80% AM at 1KHz

3V

0.15 MHz-80 MHz

6 Vm in ISM bands 

between 0.15 MHz 

and 80 MHz

80% AM at 1KHz

Conducted 

disturbances 

induced by RF 

fields.

IEC 61000-4-6

30 A/m

50 Hz or 60 Hz

30 A/m

50 Hz or 60 Hz

Rated  power 

frequency 

magnetic fields

IEC 61000-4-8

The following tables provide information on compliance of the 
equipment according to the standard EN 60601-1- 2:2015.

19

18

-The system must not be used adjacent or supported by other 
equipment. The recommendations of this manual must be followed.
-Do not use accessories, transducers, internal parts of components 
and other cables other than those previously specified by the 
manufacturer. This may result in increased emission or decreased 
electromagnetic immunity and result in improper operation.
-Portable RF communications equipment (including peripherals 
such as antenna cables and external antennas) should by used no 
closer than 30 cm to any part of the ultrasound system, including 
cables specified by the manufacturer. Otherwise, degradation of 
the performance of this equipment could result.
-To maintain basic safety in relation to electromagnetic 
disturbances during the expected service life, always use the 
system in the specified electromagnetic environment and follow the 
maintenance recommendation described in this manual.

Summary of Contents for KTR-2492

Page 1: ...uk Tel 0800 953 1666 E mail enquiries tower health co uk Transcutaneous Electronic Nerve Stimulator 20 12 09 L180 x W125mm 128G CE KTR 2492 24 4 p a in g o n e Aegis model KTR 2492 Aegis F a s t e f f...

Page 2: ...n obtained 3 Those who are or suspect they may be pregnant 4 Those with haemorrhage after acute trauma or fractures or those recovering from surgery 5 Those with skin particularly sensitive to heat or...

Page 3: ...atural pain relief mechanisms The device additionally delivers pleasant massage like stimulation Aegis can be worn discreetly under clothing and activated whenever needed via the dedicated remote cont...

Page 4: ...stic cover from side A of the gel pad Apply the gel pad to the Aegis unit as shown in the diagram Now remove side B from the gel pad Retain this plastic cover as it will be re used after treatment it...

Page 5: ...ly to cycle through different combinations of pulses to find a mode that you prefer There are 6 modes in Automatic function Each time you switch Function or mode the device intensity will reset to lev...

Page 6: ...h brand new gel pads Only use official Aegis gel pads with the Aegis device Only use one pair of pads per user of the device To purchase replacement gel pads contact Tower Health Ltd www tower health...

Page 7: ...ged The speaker is damaged The battery is running low or running out The gel pad is damaged or dirty has no stickiness or is making poor contact with the skin Skin is too oily Recharge the battery Wip...

Page 8: ...a 1060hPa c Transport environment requirements Environment temperature 25 55 Environment humidity 0 93 RH Atmospheric environment conditions 500hPa 1060hPa Indicates potential danger injury or serious...

Page 9: ...s such as electrocardiograph Do not use the product in strong direct sunlight or where there is high heat inflammable material electromagnetic radiation and or high humidity Do not disassemble repair...

Page 10: ...maging in operating rooms near active AF surgical equipment electrophysiology laboratories armored rooms or areas where short wave therapy equipment is used Do not use the system around strong electri...

Page 11: ...C 61000 4 4 3V 0 15 MHz 80 MHz 6 Vm in ISM bands between 0 15 MHz and 80 MHz 80 AM at 1KHz 3V 0 15 MHz 80 MHz 6 Vm in ISM bands between 0 15 MHz and 80 MHz 80 AM at 1KHz Conducted disturbances induced...

Page 12: ...217 Hz 2 2 0 3 0 3 0 2 0 3 0 3 28 28 9 1720 1845 1970 1700 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE 1 3 4 25 Band UMTS Pulse modulation 217 Hz 2 28 2450 2400 2570 Bluetooth WLAN 802 1 1 b g n RFID 2...

Reviews: