12
Spotlight LED 350 50VS
MA50-17 GB 2020
ENGLISH
page 8 of 20
12VAC
All lamps are connected to the transformer via 1 cable
Wiring instructions Setup 2
page 10 of 20
12VAC
Max cable length
230VAC
Cable supplied with the bulb
Separate cable is not included
Option 1.
All lights are connected directly to the
transformer with a separate cable.
This solution is preferred for installations
where a PLP-REM or PLP-REM300 control
unit is used.
Junction
box
Junction
box
Max cable length
230VAC
Cable supplied with the bulb
Separate cable is not included
Option 2.
All lights are connected to the transformer via a supply cable and
connector box.
Installation general
The recommended depth is described in later sections.
• Arming shall never be closer to the stainless material than at least 50 mm in moulded pool designs.
• Electrical installations >30V may not be placed within 500 mm of distance from any stainless material.
• When installing, corrosion-free tool with clean contact surfaces may be used.
• Store the products in its original packaging until the installation to avoid scratches and stains.
• Be careful with the assembly so that the product does not get scratched.
•
Avoid placing the concentrated dosage of chemicals next to the stainless components. Damage can occur in the case of no
pool circulation.
Electric installations
Bear in mind local electrical codes for switch box location.
The light shall always be connected via a safety transformer 12V AC of toirodal core-type (see table) to ensure correct operation
and maximum life. If more than one RGB light are installed, they shall be connected to the same transformer and via a common
power switch for synchronization.
The transformer’s power shall be greater than the total value of all lights, please refer to the table on the next page. Supplied
cable shall always be used for engagement of the light.
If the light’s external cable insulation or the inner conductor is damaged, it shall be replaced by a service technician or other
qualified person.
Recommendations
The following recommendations regarding the cable and the engagement of the lamps shall be followed to obtain the desired
function. Maximum and stable light is only guaranteed if the cross section of the cable is equal to or exceeds the table specified
values. The cable lengths are calculated with the greatest possible loss of power in the cables.
General information
Water temperature must not 40ºC.
Water must not freeze around the lamp.
Lamp must be completely immersed in the water when lit up
Recommended water quality values:
Total chlorine content: max 3.5 mg/liter (ppm)*
Chloride (salt) content: max 250 mg/liter
pH-value:
7.2–7.6
Alkalinity:
60–120 mg/liter (ppm)
Calcium hardness:
100–300 mg/liter (ppm)
Iron:
max 0.1 mg/liter *
Copper:
max 0.2 mg/liter *
Manganese:
max 0.05 mg/liter *
Phosphorus:
max 0.01 mg/liter *
Nitrate:
max 50 mg/liter *
Outside these values the product warranty does not apply.
* In accordance with EN 16713-3
RGB light’s colour modes:
Program
Name
Type
Colour
1.
Candle light
Fixed
<2000K
very warm white
2.
Warm white
Fixed
3000K
warm white
3.
Neutral white
Fixed
5000K
neutral white
4.
Cold white
Fixed
9500K
cold white
5.
Caribean blue
Fixed
cyan
6.
Blue
Fixed
blue
7.
Green
Fixed
green
8.
Red
Fixed
red
9.
Purple
Fixed
purple
10.
Yellow dynamic Slowly shifting various yellow
11.
Blue dynamic
Fast shifting
various blue