2015
OPERATIONS
MANUAL
45
TROUBLESHOOTING FILM DRIVE
NO ENABLE LIGHT
o
PULL E-STOP BUTTON OUT
o
CHECK THAT PLC S02 IS LIT GREEN
IF NOT SEE PAGE 100
o
CHECK THAT MOTOR CONTACTORS
ARE ENERGIZED
o
CHECK FOR 24VDC BEWEEN
J1 PIN 4 AND J2 PIN 12
o
TO FORCE AN ENABLE, TAKE A
JUMPER AND CONNECT
o
J1 PIN 1
TO
J1 PIN 4
o
IF THE ENABLE COMES ON AT THIS
POINT THEN THE CONTROLLER IS OK
o
IF THE ENABLE LIGHT DOSEN’T COME
ON, THEN YOU WILL NEED TO
REPLACE YOUR CONTROLLER