PRINTER NOTE: Page size 9” x 9.25”. Align this page to top, right hand corner. Back box bleeds off
top and right edge. Left side of page extends to 9.25 inches.
C
Technical Information
Specifications
DEU
Operating Environment
40
°
F to 94
°
F (+5
°
C to +34
°
C)
Relative Humidity
Operating/Non-Operating
5% - 95% (non-condensing)
Power Requirements
100 - 240 VAC (auto-sensing)
50-60 Hz
6.0 Amperes
3 x 150 watts
Rack Mount System
Dimensions (HxWxD) w/o Handles
Tower-Based System
Dimensions (HxWxL)
6.83" x 17.40" x 19.00"
17.40" x 6.83" x 19.00"
Weight (basic configuration of cabinet includes two
cooling fans)
48.0 lbs. without drives installed
56.6 lbs. with three drives installed
Altitude
-200 to 10,000 feet
Number of Drives Supported
8
Interface Transfer Rate
Up to 40 MB/sec
Host Interface
Fast/Wide SCSI-3
Drive Interface
Fast/Wide SCSI-3
HDD Termination
Automatic Termination
Electromagnetic Emissions Requirements (EMI)
FCC, Part 15, Class B
EN55022-B
Safety Requirements
UL1950
CSA C22.2 #950
TUV/EN60950
DEU (continued)
CE Compliance (EMC)
89/336/EEC EMC Directive
Shock
Operating
1.0 G, 2 - 50 ms