PRINTER NOTE: Page size 9” x 9.25”. Align this page to top, right hand corner. Back box bleeds off
top and right edge. Left side of page extends to 9.25 inches.
7
After setting the cabinet identifications you must
power cycle the subsystem. Observe normal power
cycling precautions by waiting a minimum of five (5)
seconds before adding power again.
This will reset the SCSI IDs to a default setting that
prevents a SCSI ID conflict under normal conditions.
8
Power up your computer system and run the
configuration program.
This completes the hardware installation.
S i n g l e- Bu s Cab i n et
The Single-Bus module links all of the drives in the
DEU cabinet to a single SCSI bus. This configuration
provides the user with access to the drives
independently or as a single large array.
The SCSI IDs of the drives are set by SAF-TE card
defaults to IDs 0 through 9, and are assigned
sequentially beginning with the lowest or far right
drive.
Note: SCSI ID 3 is reserved for the SAF-TE card
processor and ID 7 reserved for the RAID controller.
Caution: Ensure that the power switch is in the OFF
(O) position for both the host system and the DEU
subsystem before connecting any cables.
1
Connect one end of a one meter data cable to the
Channel #1 connector on the Host Controller.
2
Connect the other end of the data cable to the
Channel 1 SCSI connector on the upper or right side
I/O Interface card.
Note: The Channel 1 connector located on the upper or
right side I/O Interface card is the active connector
when the Single-Bus module is installed.