background image

5.

5.

四.安裝步驟

-

SC8130S/W & SC8136S/W

 1.請準備安裝位置及空間

 2.測量出風口及電源線孔的大小

   後再鑽孔

 3.櫥櫃需加強本機固定的地方

建議

   使用木條強化在櫥櫃內底部

 4.請用十字螺絲起子移除油機底板

   

卸下油機底板及燈泡電線

 

5.依安裝位置設置四支木螺釘

 6.安裝時用木螺釘扣上之後

將油機

   與櫥櫃用螺絲鎖緊

讓油機與櫥櫃

   安全不會掉落

 7.裝設電源

 8.安裝風管並用風管膠帶密封

 9.檢查風管處是否緊密及其他功能是

   否正常

10.將油機底板與燈泡重新安裝上去

11.將油杯與出風口安全網裝進油機

櫥櫃安裝說明:(如圖一)

風管膠帶

風管圈孔

電源線孔

木條

木螺釘鑰匙孔

煙罩與燈源線 

油杯與保護網

圖一

IV. Installation Procedures

-

SC8130S/W & SC8136S/W

Hood is designed for installation under a kitchen cabinet.

See Fig.1 for details.

1. Prepare duct location on hood .

7. Install electrical.

8. Install ductwork and seal with aluminum duct tape.

10. Reinstall bottom panel and reconnect lighting harness.

11. Slide oil cups into their openings on the bottom of the hood. Install protection
      grilles over each blower opening and secure with the pre-installed screw.

9. Power up hood and check for leaks around duct tape and test all functions.

3. Reinforce cabinet bottom with wood strips
    if additional strengthening is required or 
    if cabinets are framed.

4. Remove

 

bottom panel from hood using 

    a Philips screwdriver to remove each of 
    the screws.  Also remove lighting harness  
    by pressing in on the clip to release the
    lights from the internal wiring.

5. Use 4 wooden screws to secure the 
    hood to the bottom of the cabinet.

6. Lift hood onto screws located on cabinet
    bottom and lock into place. Make sure 
    all(4) key-holes cover the screws.   
    Tighten each screw to secure hood to
    cabinet. 

2. Measure and cut out duct and electrical 
    openings in cabinet or wall to match up 
    with the hood. Make sure duct opening  
    is large enough to apply aluminum duct
    tape.

Fig 1

bottom panel & 

lighting harness

oil cups & 

protection grilles

duct tape

ductwork

electrical

wood blocking

installation screws

and key-holes

Summary of Contents for SC8130S

Page 1: ...hood XP022441 1 Model number SC8230S SC8236S SC8230W SC8236W SC8130S SC8136S SC8130W SC8136W SC8830BS SC8836BS SC8830BW SC8836BW Serial Number 182766 R SC8230S SC8236S SC8230W SC8236W SC8130S SC8136S...

Page 2: ...n cooking h Alwaysusecookwareandutensilsappropriateforthetypeofandamountoffoodbeingprepared a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO...

Page 3: ...e manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance CAUTION To reduce risk of fire and to pro...

Page 4: ...xS W SC88xxBS BW 6 V Venting Instruction 7 VI Operating Instructions SC8130S W SC8136S W 8 Operating Instructions SC8230S W SC8236S W 9 Operating Instructions SC8830BS BW SC8836BS BW 10 VII Replacing...

Page 5: ...light level delay off and steam clean B Specification Chart Weight Pound Models Measurement inches Maximum Voltage Exhaust Pipe Diameter Light Maximum consumption power 120V 60Hz 7 inches LED light 8W...

Page 6: ...m Washers M6 x 1 1 2 Wood Screws 3 16 x 1 2 Screws 3 4 4 4 A C B D M6 x 1 Wood Screws M6 x 2 Wood Screws Wall Brackets 4 1 2 2 F E H G Halogen Light Suction Cup DESCRIPTION TYPE 1 4 D C DESCRIPTION T...

Page 7: ...Suction Cup SC8230S W SC8236S W DESCRIPTION HARDWARE PACKAGE CONTENTS For USA TYPE Wire Nuts 5 x 24m m Washers M6 x 1 1 2 Wood Screws 3 16 x 1 2 Screws 3 4 4 4 A C B D M6 x 1 Wood Screws M6 x 2 Wood...

Page 8: ...d right side and the screws fixed securely onto the wall to ensure the front and back of the hood are parallel In order to increase the venting efficiency of the hood it is recommended to use the 7 in...

Page 9: ...ood strips if additional strengthening is required or if cabinets are framed 4 Remove bottom panel from hood using a Philips screwdriver to remove each of the screws Also remove lighting harness by pr...

Page 10: ...ts are framed 4 Remove bottom panel from hood using a Philips screwdriver to remove each of the screws Also remove lighting harness by pressing in on the clip to release the lights from the internal w...

Page 11: ...ashing cap WARNING FIRE HAZARD Ducting Options NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Use m...

Page 12: ...fans speed is adjustable during delay off Clean function is not available during delay off 2 3 5 3 1 1 2 3 2 5 1 2 3 4 5 1 Press to start steam cleaning process 2 This button will illuminate when the...

Page 13: ...can be changed by pressing this button The LCD will indicate fan speed 5 When fans are off press this button and fans will start at last speed and light when it was last turned off at 1 Press to turn...

Page 14: ...off at 4 Speed Down 1 Press to start steam cleaning process the indication light is illuminate when the range hood is cleaning 2 When steam cleaning process is operating speed up and down buttons are...

Page 15: ...nge hood is activated or has been running for a long time be careful when handling the light bulb as it may be too hot to handle Please double check to make sure the power supply to the range hood is...

Page 16: ...ve bleach as an ingredient B Surface Cleaning and Maintenance 1 Always disconnect from power supply before cleaning 2 Clean both exterior and interior of the hood for long lasting Do not use abrasive...

Page 17: ...y the provided jar the provided jar with the range hood and take precautions not to overfill the cleaner storage unit 5 Check and empty the oil retainer after the cleaning process to prevent oil spill...

Page 18: ...failed 1 Replace main control PC board 2 PC board switch failed 2 Replace PC board switch 3 LED light failed 3 Replace LED light 3 Halogen light failed 3 Replace Halogen light Power leakage 1 Water g...