SECTION 1 GENERAL
4
1.3
GENERAL PRODUCT DESCRIPTION
The ASX-Series Power Source is high-performance AC power conversion equipment. This
series of equipment features models with power ratings from 1.5 kVA to 12.0 kVA. All systems
are designed to fit into a standard 19 inch instrument rack. The power sources are suitable for
use as frequency converters as well as sophisticated AC test power systems.
ASX power sources are typically configured with an interchangeable controller. Controller
options range from basic manual control (UPC1M and 3M) to sophisticated programmable
controllers (UPC1, UPC3, UPC12 or UPC32). The manual controller allows the user to adjust
voltage and frequency. The programmable controller provides all of the manual control
capability, plus a wide variety of control features including program storage, waveform editing,
and remote interface.
Unique to the Models 120ASX and 320ASX is the ability to operate at 150
l-n
/ 300V
l-l
. Unique to
the model 3120ASX is the ability to provide full power in either 1, 2, or 3 phase mode of
operation. The nominal (rated) output voltage range for the ASX-Series is 0-125
l-n
/ 250V
l-l.
Available current at specific voltages, as well as maximum output voltage varies by model. Refer
to section 2.1.2 for further details
Optional output transformers are available to provide higher output voltage ranges. Standard
ratios up to 2.5:1 (312/541V) as well as custom ratios are available.
The ASX-Series consists of the basic models listed below.
1.
Model 115-ASX - 1.5 kVA model, capable of 1 Phase operation. Single phase output
voltage range is 0-132
l-n
. Internal output transformer option available for higher
voltages.
2.
Model 120-ASX - 2.0 kVA model, capable of 1 or 2 Phase operation. Single phase
output voltage range is 0-150 VAC
l-n
. Output voltage in 2 Phase Mode is 0-300 VAC
L1-L2
.
Additional ranges available with custom external transformer configurations.
3.
Model 140-ASX - 4.0 kVA model, capable of 1 or 2 Phase operation. Single phase
output voltage range is 0-135 VAC
l-n
. Output voltage in 2 phase mode is 0-270VAC
L1-L2
.
External Magnetics Module available for higher output voltage ranges.
4.
Model 160-ASX -6.0 kVA model, capable of 1 or 2 Phase operation. Single phase mode
provides 6kVA of power with a 0-132 VAC
l-n
voltage range. 2 phase mode provides
4kVA of power with a 0-270VAC
L1-L2
.voltage range. External Magnetics Module
available for higher output voltage ranges.
5.
Model 315-ASX - 1.5 kVA model, capable of 1, 2, or 3 phase operation. Single and three
phase modes provide 1.5kVA of power with a 0-132 VAC
l-n
output voltage range. 2
phase mode provides 1kVA of power with a 0-264V
l1-l2
voltage range. Additional ranges
available with custom external transformer configurations.
6.
Model 320-ASX - 2.0 kVA model, capable of 1, 2, or 3 Phase operation. Single and
three phase modes provide 2.0kVA of power with a 0-150 VAC
l-n
output voltage range.
2 phase mode provides 2kVA of power with a 0-300V
l1-l2
voltage range. Additional
ranges available with custom external transformer configurations.