MAINTENANCE
SCE-20 C 9.808-371.0
4-4
BELT REPLACEMENT
1. Turn off all switches and unplug machine.
2. Remove recovery tank and brush.
3. Remove the (2) screws that fasten the solution tank to the
frame, and tilt tank back to expose the inside of the frame.
4. Loosen the (4) screws that hold the brush motor in place
and slide motor forward to release tension in belt.
5. Remove the (2) screws that fasten the vacuum shoe links
260014) to the brush housing.
6. Remove the (3) screws that fasten the side plate 260101-
260106 to the brush housing to remove belt.
NOTE: All
components associated with driving the brush will come out
with the side plate.
7. Reverse process to install belt.
Only qualified maintenance personnel are to perform the following repairs.
Seul le personnel d'entretien qualifié peut effectuer des réparations.
260101-260106
260014