Clearances
Masonry or Factory Built Fireplace
The minimum required clearances to surrounding combustible
replace
are listed below and in Fig. #1.
Minimum Clearances to Combustibles
(Measured From Insert Body)
Adjacent Sidewall ........................... 9 in. (229 mm.)
Mantel ........................................... 15 in. (381 mm.)
Top Facing .............................. 15 in. (381 mm.)
Side Facing ............................... 9 in. (229 mm.)
Mantel or Top Facing
Side F
acing
Hearth
Adjacent
Wall
Fig. # 1
36 1/2"
927mm
*42"
[1.07m]
26"
661mm
*30"
[762mm]
19 1/2"
495mm
2 3/8"
59mm
6 5/8"
170mm
19 3/4"
501mm
14 1/2"
368mm
6 1/8"
157mm
20 5/8"
525mm
9 3/4"
249mm
23 1/4"
591mm
20 1/4"
514mm
22 1/2"
571mm
Safety
READ ALL INSTRUCTIONS BEFORE INSTALLING
AND USING THIS APPLIANCE. FAILURE TO FOLLOW
INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
We strongly recommend that smoke detectors be installed.
If smoke detectors have been previously installed, you may
notice that they are operating more frequently. This may be
due to curing of stove paint or fumes caused by accidentally
If necessary, relocate them to reduce their sensitivity.
SAFETY NOTICE: If this stove is not properly installed, a
tions and installation inspection requirements in your area.
ed by the Wood
Energy Technical program (WETT) - in Canada, Hearth
Education Foundation (HEARTH) - in U.S.A. (or equivalent)
are strongly recommended.