Pacific energy VISTA D SERIES Installation And Operating Instructions Manual Download Page 18

Warranty Information

Pacifi c Energy Limited Lifetime Warranty

Wood Products

Pacifi c Energy extends the following warranty coverage to the original registered purchaser of the product:

LTD Lifetime Coverage (10 years)

Limited lifetime coverage is extended to the following components (parts only) porcelain fi nish, glass (glass for thermal 
breakage only, not impact), plating, fi rebox and baffle.

3 Year  Comprehensive

Pacifi c Energy will replace or repair any part found to be defective (parts and labor) for three years from the date of pur-
chase.

This coverage includes electrical components (blowers, speed controls and thermal switches).

Conditions:

Your stove has been designed to perform in the harshest climates in North America. You can be confi dent that 
under normal use your stove will be trouble free for many years.  If your stove is prematurely deteriorating this is 
a signifi cant indicator of improper usage, for example; excessive draft, heating to large an area, contaminated fuel 
- such as high sodium content or plastics and chemicals. Please be aware, these conditions may be reasons to 
void your warranty.

For wood products 

- All installations must be installed according to all applicable local and national codes. It is the re-

sponsibility of the installer to ensure the unit is operating correctly at installation.

Any part that shows in our judgment evidence of defect shall be repaired, replaced or refunded at Pacifi c Energy’s option. 
The defective part may be required to be returned to Pacifi c Energy or an accredited agent, transportation prepaid.

Porcelain

 is warranted for gloss retention. Certain colors may darken when heated and return to the original shade when 

cool.

Glass

 is warranted against thermal breakage.

Plating

 is warranted against tarnishing. Gold plating may attain a deeper color with use.

Exclusions

Limited Lifetime coverage - Lifetime coverage is limited to the repair, replacement or refund of the indicated parts only. 
Labor charges are not covered under the lifetime warranty.

The following items are not included in the Lifetime Warranty: fi rebox rails and heat shields.

The following parts are not warranted: fi rebrick, gaskets and ceramic fi ber blankets.

This warranty does not apply to any part that shows evidence of misuse, abuse, improper installation, accident, lack of 
maintenance, or modifi cation.

Pacifi c Energy shall in no event be liable for any special, indirect or consequential damages of any nature whatsoever 
which are in excess of the original purchase price of the product.

Pacifi c Energy is not responsible for installation, operational or environmental conditions beyond our control.
(The company may, at its discretion, discharge all obligations by refunding the wholesale price of the defective part.)

For Warranty claims, please contact your nearest Pacifi c Energy dealer.

18

 VISTA 

INSERT-D 

20

051

6

-2

0

Summary of Contents for VISTA D SERIES

Page 1: ...may result For your safety follow the installation instructions Contact local building or fire officials about restrictions and installation inspection requirements in you area IMPORTANT THESE INSTRU...

Page 2: ...Label 19 PLEASE SAVE THESE INSTRUCTIONS This manual describes the installation and operation of the Pacific Energy VISTA INSERT wood heater This heater meets the 2015 U S Environmental Protection Agen...

Page 3: ...22 1 2 571mm Safety READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING THIS APPLIANCE FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH We strongly recommend tha...

Page 4: ...System Top baffle board blanket Baffle Top heat shield and mounting bolt Baffle Gasket Brick Rails Manifold Blower The blower should be cleaned out a minimum every six months by using a vacumn on the...

Page 5: ...insert must be protected from hot embers by non combustible material ex tending 16 406mm USA and 18 457mm CANADA to the firing side and 8 203mm to other sides of the unit Consult CAN CSA B365 Installa...

Page 6: ...r other obstructions especially if it has not been in use for some time Theexistingfireplacedamperistobelockedopenorremoved completely WARNING Do not remove bricks or mortar from your existing firepla...

Page 7: ...ert Note Forbetteraccess thetopofthecasingmayberemoved Fig 6 If it is necessary to get access to the connector pipe through the flue outlet of the Insert the baffle can be removed see Baffle Removal s...

Page 8: ...3 Center assembled surround on the firebox and slide gently into position Fig 10 Be careful to align notches in surround with top Engage the mounting brackets over the mounting screws in the casing s...

Page 9: ...l Code and in the USA with the National Electrical Code ANSI NFPA 70 lat est edition Combustion Air Consult local building codes regarding combustion air sup ply Intake or combustion air can be suppli...

Page 10: ...Close door 5 Begin normal operation after a good coal base exists and wood has charred Curing of the Paint Finish When burning your stove for the first 2 3 times it is very im portant that the room be...

Page 11: ...Energy Technical Training program WETT in Canada HearthEducationFoundation HEARTH inU S A are strongly recommended Over Firing Over firing can be caused by operating the unit with the door open damag...

Page 12: ...nite chimney fires Thesearehotfires suchaswhenburninghousehold trash cardboard Christmas tree limbs or even ordinary fuel wood eg with a full load on a hot bed of coals and with the air inlet wide ope...

Page 13: ...estricted check flue Provide outside air for combustion Glass is Dirty 1 See 1 2 and 3 above 2 Door Gasket leakage Replace gasket Check latch Low Heat Output 1 Wood is wet Use dry wood 2 Fire too smal...

Page 14: ...heater in the upright position install firebricks as follows First install 4 firebricks against the rear wall Next install the side firebricks 2 each side Lastly place 4 firebricks on the bottom of t...

Page 15: ...s required 5096 99 Firebrick Set BRIC VISTA 12 Brick Rail Set VIST RAILSET 15 Baffle VIST BAFKIT 16 Flame Shield c w Bolt and Nut VINC 2305 17 Baffle Gasket SSER 1395 18 Door Catch c w Bolt WODC 1461...

Page 16: ...nap Disc Switch Wire VINC 5032 7 Snap Disc Switch 5027 2 All parts may be ordered from your nearest Pacific Energy dealer Contact Pacific Energy for the location of the dealer nearest you 8 Rocker Swi...

Page 17: ...with the appliance Attach hearth trim to the bottom of the surround with clips provided The clips are installed up through the trim and into the surround This kit contains 1 Hearth Trim 4 Spring Clips...

Page 18: ...y part that shows in our judgment evidence of defect shall be repaired replaced or refunded at Pacific Energy s option The defective part may be required to be returned to Pacific Energy or an accredi...

Page 19: ...ID WOOD FUEL FIREPLACE INSERT APPAREIL DU TYPE INSERTION DE COMBUSTIBLE SOLIDE DE CHEMIN E CERTIFIED FOR USE IN CANADA AND U S A CERTIFIE AU CANADA ET AUX ETATS UNIS TESTED TO PROUV SELON ULCS628 93 U...

Page 20: ...hone 1 250 748 1184 Web site http www pacificenergy net 2975 Allenby Rd Duncan B C V9L 6V8 PACIFIC ENERGY FIREPLACE PRODUCTS LTD Phone 1 250 748 1184 Web site http www pacificenergy net 2975 Allenby R...

Reviews: