Flue adapters
The Tofino i40 uses 3” flex tubing for the air intake and 4” flex tubing for the air exhaust. The Tofino i40 ships
with a flue adapter which fits onto the top of the firebox and is affixed with a connection bolt (Figure 11).
Depending on the amount of room available for the installation of the Tofino, the installer may want to remove
the flue adapter and attach it to the flex tubes which will have previously been inserted down the chimney.
The installer must make sure that the air intake vent and air exhaust vents attach to the correct ports on
both the flue adapter and the vent terminal. The vent terminal and the flue adapter are marked with an “I” (air
intake) and “E” (air exhaust).
3” Air intake
4” Exhaust
Figure 10: 4 x 3 inch Flue adapter.
Flue adapter
Connection
bolt
Figure 11: Tofino with flue adapter mounted.
Venting
10’ to 40’ Use the 3x4 Configuration
10’ to 28’ Use the 3x4 and the 4” to 3” adapter Configuration
12
051119-48 100000300
i40 TOFINO