Mobile Home Installation
Minimum
Clearance to
Combustibles
Procedure:
CAUTION: THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME FLOOR, WALL AND CEILING/ROOF
MUST BE MAINTAINED.
Note: See "Combustion Air" section onpage 9.
1. Position stove and floor protection with hole for combus-
tion air in accordance with the clearances as stated on the
label and in Figure #1.
2. Mark the position for the hole in the ceiling and roof by
using a string and plumb-bob.
3. Check that the intended location will not interfere with floor
joists, ceiling joists or rafters before proceeding further.
4. Cut a hole in the ceiling and roof to suit the chimney system
and frame in the sides. The chimney support is mounted to
the framing.
5. Assemble chimney sections so the finished length is resting
on the support and protruding through the roof. Avoid
having joints between ceiling and roof. Install radiation
shield. Assemble flashing and storm collar and be sure to
maintain the vapour barrier at this point. (Seal securely.)
Attach rain cap and check flashing for leaks.
6. Install connector as per manufacturer's instructions.
7. Attach stove to flooring using two 1/4" x 2" or longer lag
screws.
Warning:
Under no circumstances is this heater to be installed
in a makeshift or "temporary" manner. It may be fired only after
the following conditions have been met.
-
DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
-
DO NOT INSTALL IN A SLEEPING ROOM.
- Outside air supply must be used for Mobile Home installations
see Figure #2, Page 7.
- The services of a competent or certified installer, (certified by
the Wood Energy Technical Training program (WETT) - in
Canada, Hearth Education Foundation (HEARTH) - in U.S.A.,)
are strongly recommended.
Clearances
This heater must be installed with listed double-wall connector
and compatible chimney system listed on page 7.
Clearances to combustible surfaces and materials are shown
below in Figure #1 and Figure #2, page 7.
Clearances may be reduced with various heat insulating mate-
rials. Consult local fire codes and authorities for approval.
NOTE:
Longer chimney lengths and different pitch flashings
may be used. All other parts listed must be installed (see Figure
#2, Page 7). Install all components to the connector or chimney
manufacturer's installation requirements. Consult your chim-
ney supplier for installation advice.
FIG. #1
Double Wall Connector - Residential
Single Wall Connector - Residential
Alcove: Min. Height 7 1/2'
Max. Depth 4'
Double Wall Connector - Mobile Home