background image

 

 23

©PACIFIC ENERGY FIREPLACE 
PRODUCTS LTD.

Label

 A.       

12 IN. / 305 MM 

   12 IN. / 305 MM

 B.

12 IN. / 305 MM 

  

12 IN./305 MM

 C.

8 IN. / 203 MM 

     8 IN. / 203 MM

 D.    23.5

 IN. / 597 MM 

23.5 IN. / 597 MM

 E.

15 IN. / 381 MM 

15 IN. / 381 MM

 F.

        
17 IN. / 432 MM 

   17 IN. / 432 MM

 A.         

8 IN. / 203 MM 

     8 IN. / 203 MM

 B.

5 IN. / 127 MM 

     5 IN. / 127 MM

 C.

3 IN. / 76 MM 

       3 IN. / 76 MM

 D.

19 IN./483 MM     

   19 IN. / 483 MM

E.
7.5 IN. / 191 MM                    7.5 IN. / 191 MM

 F.

    

11.5 IN. / 292 MM 

11.5 IN. / 292 MM

 A.      8

 IN. / 203 MM 

     8 IN. / 203 MM

 B.
5 IN. / 127 MM 

     5 IN. / 127 MM

 C.

N/A
 

       3 IN. / 76 MM

 D.
19 IN./483 MM 

   19 IN. / 483 MM

 E.

7.5 IN. / 191 MM 

  7.5 IN. / 191 MM

 F.

   

N/A
 

11.5 IN. / 292 MM

CERTIFIED FOR CANADA

 AND U.S.A. 

 - SERIES / SÉRIE: 

A

   MODEL

 / MODÈLE: 

NEO 2.5

NEWCASTLE 2.5     NEOST

ONE

LISTED ROOM HEA

TER, SOLID FUEL

 TYPE.

ALSO FOR USE IN MOBILE HOMES

TESTED T

O/ ÉPROUVÉ SELON: CAN/ULC S627-00 

AND IN THE USA

 CONFORMS T

O UL

 1482-201

1

• 

INST

ALL
 AND USE IN 

ACCORDANCE WITH THE MANUF

ACTURER’S INST

ALLA

TION 

AND OPERA

TING 

 INSTRUCTIONS.

• 

CONT

ACT LOCAL

 BUILDING OR FIRE OFFICIALS 

ABOUT RESTRICTIONS, INST

ALLA

TION PERMIT 

AND 

 

INSPECTION 

IN 

YOUR AREA.

• 

DO NOT CONNECT THIS UNIT T

A CHIMNEY

 FLUE SER

VING 

ANOTHER 

APPLIANCE.

• 

USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECT

OR.

• 

CAN BE CONNECTED T

A LINED MASONR

Y CHIMNEY

 SUIT

ABLE FOR USE WITH SOLID FUELS.

• 

DO NOT OBSTRUCT THE 

AIR INLETS BENEA

TH THE HEA

TER.

• 

SEE LOCAL

 BUILDING CODE 

AND MANUF

ACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED 

WHEN P

ASSING 

A CHIMNEY

 THROUGH 

A COMBUSTIBLE W

ALL
 OR CEILING.

• 

DO NOT P

ASS 

A CHIMNEY

 CONNECT

OR THROUGH 

A COMBUSTIBLE W

ALL
 OR CEILING.

• 

MINIMUM CLEARANCE BETWEEN SINGLE W

ALL
 CHIMNEY

 CONNECT

OR 
AND COMBUSTIBLE MA

TERI-

ALS-18INCHES/455MM.  CLEARANCE MA

Y BE REDUCED BY

 THE USE OF LISTED PIPE SHIELDS, W

ALL
 

PROTECT

ORS OR OTHER MEANS 

APPROVED BY

 LOCAL

 BUILDING OR FIRE OFFICIALS.

• 

COMPONENTS REQUIRED FOR MOBILE HOME 

AND 

ALCOVE INST

ALLA

TION: OUTSIDE 

AIR KIT

.

 

BOTH CHIMNEY

 SYSTEM 

AND CONNECT

OR MUST BE LISTED T

O:

 

IN CANADA

 -  ULC S-641 LISTED CONNECT

OR 
AND ULC-S-629 LISTED CHIMNEY

 

IN USA

 -  UL-103 HT LISTED CONNECT

OR 
AND CHIMNEY

 

• 

USE COMPONENTS SPECIFIED IN P

ACIFIC ENERGY

 INST

ALLA

TION INSTRUCTIONS.

• 

OPTIONAL

 COMPONENTS - BLOWER(WODC.BLOW), F

AN ELECTRICAL

 RA
TING: 1

15V
, 60HZ, .5 

AMP

.

 

DO NOT ROUTE POWER CORD BENEA

TH HEA

TER.

• 

CAUTION: RISK OF EXCESSIVE TEMPERA

TURES - KEEP

 ASH DUMP

 CLOSED DURING FIRING OF THE 

HEA
TER.

• 

OPERA

TE ONL

Y WITH FEED DOOR CLOSED.  OPEN T

O FEED FIRE ONL

Y.

• 

KEEP

 FURNISHINGS 

AND OTHER COMBUSTIBLE MA

TERIALS WELL

 A

W

AY

 FROM HEA

TER.

• 

REPLACE GLASS ONL

Y WITH CERAMIC GLASS.

 

HORIZONT

AL

 CONNECT

OR NOT PERMITTED IN MOBILE HOMES

 AS TESTED - PIPE SHIELD MA

Y BE REQUIRED BY

 LOCAL

 AUTHORITIES.

COMBUSTIBLE 

ALCOVE SIZE : DEPTH - 3 FT

. / .91 M MAX., HEIGHT 7 FT

. / 2.1 M MIN., WIDTH 43 IN. / 1.09 M 

MIN.

 

COMBUSTIBLE FLOOR MUST BE PROTECTED BY

 A

 CONTINUOUS NON-COMBUSTIBLE MA

TERIAL

 EX-

TENDED T

O THE FRONT

, SIDES 

AND BACK 

AS INDICA

TED.

• 

FOR USE WITH SOLID WOOD FUEL

 ONL

Y. ST
OVE DESIGNED T

O BURN CORDWOOD ONL

Y. BURNING 

OTHER MA

TERIALS MA

Y CAUSE DAMAGE T

O ST

OVE OR HOME.

MINIMUM CLEARANCES T

COMBUSTIBLE MA

TERIALS/

DÉGAGEMENTS 

MINIMALES AUX 

MA

TÉRIAUX COMBUSTIBLES

DO NOT

 REMOVE 

THIS LABEL

RACCORD

VERTICAL

 CONNECT

OR      

RACCORD

HORIZONT

AL

 CONNECT

OR 

RESIDENTIAL

 CLOSE CLEARANCE INST

ALLA

TION 

USING DOUBLE W

ALL
 CONNECT

OR/ 
INST
ALLA

TION 

RÉSIDENTIELLE 

AVEC DÉGAGEMENT MINIMAL, UTILISANT 

UN RACCORD DE MUR DOUBLE

* ALCOVE 

INST
ALLA

TION

USING DOUBLE W

ALL
 

CONNECT

OR/
* INST

ALLA
TION 

EN 

ALCÔVE UTILISANT UN 

RACCORD DE MUR DOUBLE

RESIDENTIAL

 INST

ALLA

TION 

USING SINGLE W

ALL
 CONNECT

OR/

INST
ALLA

TION RÉSIDENTIELLE UTILISANT UN 

RACCORD DE MUR SIMPLE

 IN CANADA

 
G. 

18 INCHES / 457 MM

 AU 
CANADA

 

H. 

8 INCHES / 200 MM

 

I. 

8 INCHES / 200 MM

 IN U.S.A. 

G. 

16 INCHES / 405 MM

 AUX 

ÉT

ATS-UNIS

 H. 

3.2 INCHES / 81 MM

 

I. 

0 INCHES / 0 MM

MOBILE

HOME INST

ALLA

TION

USING DOUBLE W

ALL
 

CONNECT

OR/ 
INST
ALLA
TION 

EN MAISON MOBILE UTILISANT 

UN RACCORD DE MUR DOUBLE

ETL#4001507

• 

INST
ALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INST

ALLA

TION ET D’OPÉRA

TION FOURNI 

AVEC L

’APP
AREIL..

• 

CONT

ACTEZ LES OFFICIELS DE LA

 CONSTRUCTION OU DE SER

VICE D’INCENDIE POUR DES INFORMA

TIONS QUANT 

AUX 

RESTRICTIONS. PERMIS D’INST

ALLA

TION ET INSPECTIONS DANS VOTRE RÉGION.

• 

NE RELIEZ P

AS CET 

APP
AREIL

 À UN CONDUIT DE CHEMINÉE DESSER

VANT DÉJÀ UN 

AUTRE 

APP
AREIL

 

• 

UTILISER UN TUY

AU DE RACCORDEMENT DE 6 PO (150 MM) DIAM., HOMOLOGUÉ OU NOIR 24 MSG (MIN.)

• 

PEUT ÊTRE CONNECTÉ À UNE CHEMINÉE DE MAÇONNERIE GAINÉ PRÊTE À L

’EMPLOI 

AVEC DES COMBUSTIBLES SOLIDES.

• 

N’OBSTRUEZ P

AS L
’ESP
ACE SOUS LE CAISSON DU POÊLE

• 

CONSUL

TEZ LE CODE LOCAL

 DE CONSTRUCTION ET LES INSTRUCTIONS DU F

ABRICANT QUANT 

AUX PRÉCAUTIONS À 

PRENDRE LORSQUE VOUS F

AITES P

ASSER UNE CHEMINÉE À TRA

VERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE MA

TÉ-

RIAUX COMBUSTIBLES.

• 

LE TUY

AU DE RACCORDEMENT DE CHEMINÉE NE DOIT P

AS TRA

VERSER UN MUR OU PLAFOND EN MA

TÉRIAUX COMBUS-

TIBLES.

• 

DÉGAGEMENT MINIMAL

 ENTRE UN RACCORDEMENT DE CHEMINÉE À SIMPLE P

AROIS ET UN MUR ET T

OUT MA

TÉRIEL

 

COMBUSTIBLE - 18 POUCES / 455 mm.  CE DÉGAGEMENT PEUT ÊTRE RÉDUIT EN UTILISANT DES PROTECTEURS DE TUY

AUX 

CLASSÉS, PROTECTEURS DE MUR OU 

AUTRES MOYENS 

APPROUVÉS P

AR LES OFFICIELS DE LA

 CONSTRUCTION OU DU 

SER
VICE D’INCENDIE DE VOTRE RÉGION.

 

CONNECTEUR HORIZONT

AL

 NON PERMIS DANS MAISONS MOBILES

• 

PIÈCES REQUISES POUR INST

ALLA

TION EN MAISON MOBILE OU EN 

ALCÔVE:  PRISE D’AIR EXTÉRIEUR 

ET L

’UN DES RACCORDS SUIV

ANTS:  EN COMBINAISON 

AVEC L

’UN DES SYSTÈMES DE CHEMINÉE COM-

PA

TIBLES SUIV

ANTS: 

  

CANADA-TUY

AU DE RACCORDEMENT HOMOLOGUÉ ULC S-641 ET CHEMINÉE HOMOLOGUÉE ULC S-629. 

ÉT

ATS-UNIS - TUY

AU DE RACCORDEMENT ET CHEMINÉE HOMOLOGUÉS UL-103HT

.

• COMPOSANTS OPTIONNELS: VENTILA

TEUR (WODC.BLOW), 

ALIMENT

ATION ÉLECTRIQUE DU VENTILA

TEUR : 1

15 V
, 60 HZ, 0.5 

AMP
. LE CORDON D’ALIMENT

ATION ÉLECTRIQUE NE DOIT P

AS ÊTRE PLACÉ SOUS LE POÊLE. 

 

LE FIL

 ÉLECTRIQUE NE DOIT P

AS ÊTRE PLACÉ SOUS LE POÊLE

• 

ATTENTION: RISQUE DE TEMPÉRA

TURES EXCESSIVES - GARDES LE TIROIR DE CENDRES FERMÉ PENDANT L

’ALLUMAGE DU 

POÈLE.

• 

OPÉREZ SEULEMENT LORSQUE LA

 PORTE D’ALIMENT

ATION EST FERMÉE.  

• 

OUVREZ SEULEMENT POUR 

ALIMENTER LE FEU.

• 

GARDEZ LES MEUBLES ET 

AUTRES MA

TÉRIAUX COMBUSTIBLES BIEN ÉLOIGNÉS DU POÊLE.

• 

REMPLACES LA

 VITRE 

AVEC UNIQUEMENT DE LA

 VITRE CÉRAMIQUE.

 CONNECTEUR HORIZONT

AL

 NON PERMIS DANS MAISONS MOBILES



TEL
 QUE TESTÉ: UN ISOLANT THERMIQUE POUR TUY

AU PEUT ÊTRE EXIGÉ P

AR LES 

AUT
ORITÉS LOCALES. * DIMENSIONS 

D’ALCÔVE EN MA

TÉRIAUX COMBUSTIBLES: PROFONDEUR MAX.: 3 PIEDS (0,91 M), HAUTEUR MIN.: 7 PIEDS (2,1 M), LARGEUR 

MIN.: 43 PO (1,09 M).

LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ P

AR UN MA

TÉRIEL

 NON-COMBUSTIBLE T

OUT D’UNE PIÈCE QUI DOIT 

S’ÉTENDRE DE P

AR LE DEV

ANT
, LES COTÉS ET L

’ARRIÈRE TEL

 QU’INDIQUÉ.

·  

 POUR UTILISA

TION 

AVEC BOIS SOLIDE SEULEMENT

. LE POELE CONÇU POUR BRÛLER BOIS DE CORDE 

SEULEMENT

. LA
 COMBUSTION D’AUTRES MA

TÉRIELS PEUT

.

A. 

SIDEW

ALL
 T

O UNIT/

MUR DE CÔTE / 

APP
AREIL

B. 

BACKW

ALL
 T

O UNIT/

M

UR DE FOND / 

APP
AREIL

C. 

CORNER T

O UNIT/

COIN 
/ APP
AREIL

D. 

SIDEW

ALL
 T

O CONNECT

OR/

MUR DE CÔTE / RACCORD

E. 

BACKW

ALL
 T

O CONNECT

OR/

MUR DE FOND / RACCORD

F. 

CORNER T

O CONNECT

OR/

COIN / RACCORD

BACK  I

HEA
TER

G

SIDE

H

FRONT

SIDE

H

COTE

COTE

DEV
ANT

POELE

DOS

RACCORD

VERTICAL

 CONNECT

OR      

RACCORD

HORIZONT

AL

 CONNECT

OR 

MADE IN CANADA/ 

FABRIQUÉ AU 

CANADA


 F 
 M 
 A

 

 M 
 J 
 J 
 A

 

 S 
 O 

 D

2014 

2015 2016 2017 

2018 

2019

DA

TE OF MANUF

ACTURE/ 

DA

TE DE MANUF

ACTURE

NE25-1

U.S. ENVIRONMENT

AL

 PROTECTION 

AGENCY

 CERTIFIED T

O COMPL

Y WITH JUL

Y, 

1990, P

ARTICULA

TE EMISSION ST

ANDARDS// 

CERTIFIÉ P

AR L
’AGENCE DE PROTECTION DE 

L’ENVIRONNEMENT DES ÉT

ATS-UNIS (EP

A) EN 

ACCORD 

AVEC LES ST

ANDARDS D’ÉMISSION DE 

PARTICULES DE JUILLET 1990

5050.900

201014

MANUF

ACTURED BY/ 

FABRIQUÉ P

AR:

PACIFIC ENERGY

 FIREPLACE PRODUCTS L

TD.

2975 

ALLENBY

 RD., DUNCAN, BC  V9L

 6V8

HOT WHILE IN OPERA

TION.  DO NOT T

OUCH.  KEEP

 CHILDREN, CLOTHING 

AND FURNITURE 

AW

AY

.  CONT

ACT MA

Y CAUSE SKIN BURNS.  SEE NAMEPLA

TE 

AND INSTRUCTIONS.// 

CHAUD LORSQU’EN OPÉRA

TION.  NE P

AS T
OUCHER, TENEZ LES 

ENF
ANTS ET LES VÊTEMENTS BIEN À L

’ÉCART

.  LE CONT

ACT PEUT CAUSER DES BRÛLURES 

À LA
 PEAU.  CONSUL

TEZ LA

 PLAQUE CE CONSTRUCTEUR ET LES INSTRUCTIONS.

CAUTION

ADJACENT

 W

ALL

BACK W

ALL

D

A

SIDE WALL

B

E

ADJACENT WALL

F

C

MUR COTE

MUR ARRIERE

MUR ADJACENT

MUR ADJACENT

SN-

502

(T

ype 1 fl

 oor 

pr

ot

ect
or - appr

ov

ed 

to UL1

61

8)

Minim

um 
20G

st

eel

310316-24

Summary of Contents for NEO 2.5

Page 1: ...ctions Contact local building or fire officials about restrictions and installation inspection requirements in your area IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER MODEL NEO 2 5 SER...

Page 2: ...Blower Operation 15 Optional Outside Air Adaptor 15 Troubleshooting 16 Replacement Parts NEO 2 5 17 Understanding Operating Your Pacific Energy Stove 18 Firebrick Installation Instructions 19 Label 2...

Page 3: ...ldup Chimney Fires The result of excessive creosote buildup is a chimney fire Chimney fires are dangerous Chimney inside temperatures can exceed 2000 F 1093 C This causes much higher than normal tempe...

Page 4: ...er no circumstances should you attempt to barbecue in this heater How to Test Your Wood Add a large piece of wood to the stove when it has a good large bed of coals It is dry if it is burning on more...

Page 5: ...dfurtherforward thanflushwiththepedestals Donotstorepaperorotherstove lighting devices within the pedestal area Although storing wood under the unit is possible it is not recommended NOTE Refer to loc...

Page 6: ...ur dealer Use 18 457mm x 10 1 4 260mm x 5 mm Ceramic glass only Do not substitute with any other type To remove broken glass remove the door gasket and then undo the eight screws securing the gasket g...

Page 7: ...ube in the back of the firebox Back side of airwash chamber located in the upper front of firebox Baffle locking pin Boost tube cover located in center of manifold bottom front of firebox When Cleanin...

Page 8: ...hold down brackets away from the stove Side Panel Removal Installation 1 To remove the panels first remove the screws that secure the panel to the rear shield Fig 3 2 Disengage the the tabs in the fr...

Page 9: ...raw outside air from behind the stove an outside air adaptor may be required see Optional Blower section Cut or drill a 4 102mm hole through a wall behind the unit Use an appropriate household 4 102mm...

Page 10: ...ance The chimney connector should not pass through an attic roof space closet or similar concealed space floor or ceiling Where passage through a wall or partition of combustible material is desired t...

Page 11: ...arance to Combustibles 6 Cut a hole in the ceiling and roof to suit the chimney system and frame in the sides The chimney support is mounted to the framing 7 Assemblechimneysectionssothefinishedlength...

Page 12: ...r 48 1219 mm 3 914 mm Minimum Hooded vent or 90 elbow turned down The chimney may incorporate an offset To do this safely all sections of listed connector offset elbows and chimney section must be scr...

Page 13: ...7 2 1m Ceiling Height Non combustible floor protector 48 1219 mm Hooded vent or 90 elbow turned down Ensure that the Masonry chimney meets all National Fire Protection Association and local building c...

Page 14: ...ce FIG 9 Mobile Home Installation Procedure CAUTION THESTRUCTURALINTEGRITYOFTHEMOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED The services of a competent or certified installer certified b...

Page 15: ...o turn on as the stove heats up to operating temperature It will also shut the blower off after the fire has gone out and the unit cooled to below a useful heat output range Manual Tomanuallyoperateth...

Page 16: ...ve Creosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overnight...

Page 17: ...NE16 7817 10 Side Shield Bracket LHS NE25 78485 All parts may be ordered from your nearest Pacific Energy dealer Use www pacificenergy net for the location of the dealer nearest you 10b Side Shield Br...

Page 18: ...design Traditionalwoodstoveshadabasiccombustionsystemwhich allowed a considerable amount of heat energy to escape up the chimney as unburned gases and particulates smoke PacificEnergyhasdesignedasyst...

Page 19: ...ckage contains 18 full size firebricks as well as 6 various cut size bricks With the heater in the upright position install firebricks as follows Install the rear firebricks 4 full size two on each si...

Page 20: ...correctly at installation Any part that shows in our judgment evidence of defect shall be repaired replaced or refunded at Pacific Energy s option The defective part may be required to be returned to...

Page 21: ...21 PACIFIC ENERGY FIREPLACE PRODUCTS LTD 310316 24...

Page 22: ...22 PACIFIC ENERGY FIREPLACE PRODUCTS LTD 310316 24...

Page 23: ...DE LA CONSTRUCTION OU DE SERVICE D INCENDIE POUR DES INFORMATIONS QUANT AUX RESTRICTIONS PERMIS D INSTALLATION ET INSPECTIONS DANS VOTRE R GION NE RELIEZ PAS CET APPAREIL UN CONDUIT DE CHEMIN E DESSER...

Page 24: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan B C V9L 6V8 For technical support please contact your retailer Web site http www pacificenergy net Printed in Canada...

Reviews: