1. Position
the glass retainer’s frame so
that the studs on unit align with holes
in frame. Secure using 12
11/32” nuts
as shown in
Figure 29.
CAUTION: Over tightening of nuts
could result in glass fracturing.
2. Insert and lower the outer door by
positioning the door’s pins into the slits
in the firebox frame as shown in
Figure
30.
Removal
1. Lift the outer door up and pull away
from unit.
2. Remove the 12
11/32” nuts as shown
in Figure 29. Carefully remove the
glass retainer with the glass by tilting
the top towards you.
Fan Installation / Removal
Installation
1. Connect wiring to the fan and insert into the
fireplace through the side of the unit.
2. Insert both screws into the fan access panel to
attach the fan to the unit, as in Figure 31.
3. Replace side surround as shown on page 28.
Figure31: Fan Install/Removal
Removal
1. Start by turning off the main gas supply to fireplace and disconnect the gas supply from the
1/2”
flare fitting as seen in Figure 23. Also, disconnect the power cord from the unit.
2. Remove the ceramic cladding as shown on page 28.
3. Remove the two (2) screws from the panel as shown in Figure31 and pull the fan out of unit. You
will have to disconnect the wires from the fan before you can remove it completely.