10' Vent Pipe Kit

ESTD.VP10

This vent kit is for use with these models: The ESTATE and The ESTEEM fireplaces.
Please refer to the Installation Instructions provided with the appliance for proper
venting installation.

This box contains:

10' ........... 4" Flex Vent

10' ........... 8" Flex Vent

1 .............. 4" Vent Connector

1 .............. 8" Vent Connector

1 .............. Firestop

4 .............. Pipe Support Sets (2 pc.)

5 .............. Pipe Spacer

8 .............. #10 x 5/8" Teks screws

8 .............. #8 x 1/2" sheet metal screws

f i r e - p a r t s . c o m

Summary of Contents for G Series

Page 1: ...plier s instructions Ifyoucannotreachyourgassupplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY IMP...

Page 2: ...TIONAL VENTING 16 OPTIONAL SNORKEL VENT TERMINAL 19 MANUFACTURED MOBILE HOME 20 GAS SUPPLY 20 WALL SWITCH OR THERMOSTAT 20 BURNER REMOVAL 21 OPTIONAL BRICK PANELS INSTALLATION 21 EMBER MATERIAL INSTAL...

Page 3: ...n Do not use this heater if any part has been under water Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which...

Page 4: ...ces on the following page and the Screen Front Framing Section Minimum Clearances to Combustibles Side standoffs 0 in 0 mm Back standoffs 0 in 0 mm Top standoffs 0 in 0 mm Adjacent sidewall 6 in 152 m...

Page 5: ...wall or chase it is recommended that the outer walls be insulated to same degree as other exterior walls Do not place the fireplace directly against the insulation Cover the insulation and plastic va...

Page 6: ...vent system is installed Heavier construction may be required for some Fig 7 Fig 6 Fig 5 Fig 4 NAILING TABS CORNER FRAMING DIMENSIONS FRAMING DIMENSIONS Examples of Common Installation Locations insta...

Page 7: ...eplace to framing with screws or nails see Fig 4 The tabs will allow for a finishing wall up to 3 4 inch thick if thicker unit must be spaced outwards accordingly Due to higher temperatures with the S...

Page 8: ...op vent outlet 4 Secure in place with screws previously removed see Fig 8b Fig 8a Black Sealant VENT ADAPTER INSTALLATION The Estate fireplace easily adapts to use either the Pacific Energy Flex Vent...

Page 9: ...nd run mustbeconstrainedtothebounda ries of this chart VERTICAL RISE HORIZONTAL RUN PACIFIC ENERGY WALL TERMINATION VENTING Fig 8d NOTE At 31 1 2 up the maxi mum horizontal rear exit vent length is 18...

Page 10: ...llation location of the restrictor see Fig 21 Remove the glass front and the two rear logs Remove the one top mounting screw shown in Fig 8f place the restrictor over the hole and replace the one scre...

Page 11: ...t maximum 2 foot intervals see Fig 10 Spacers may have to be closer if pipe is bent 90 1 Bend pipe spacer around the 4 inch inner pipe With endsofspaceroverlapped bendlockingtabsintoplace see Fig 10 2...

Page 12: ...ntervals see Fig 9 Spacers may have to be closer if pipe is bent 90 The vent system must be supported approximately every 3 feet Use pipe support straps provided with kit to maintain a 1 inch clearanc...

Page 13: ...nded above meter regulator assembly AIR SUPPLY INLET VENT TERMINAL GAS METER FIXED CLOSED FIXED CLOSED OPERABLE OPER ABLE INSIDE CORNER DETAIL AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installatio...

Page 14: ...d the 8 inch outer flex pipe through the roof opening Slip the flex pipe a minimum of 1 1 2 inches over the support sleeve Secure pipe to the sleeve with screws provided Seal the joint and screw heads...

Page 15: ...m of 1 1 2 inches over the inner collar of the roof vent terminal Secure to the collar with screws provided Seal the joint and screw heads using the high temperature sealant provided 8 Lower the roof...

Page 16: ...1 3 4 INCHES FROM ANY VERTI CAL AND HORIZONTAL VENT SECTIONS OF THE SIMPSON DURA VENT DIRECT VENT GS SYSTEM Fig 19b WALL TERMINATION TOP VENTING DURA VENT GS VERTICAL RISE HORIZONTAL RUN 1 2 3 4 5 1...

Page 17: ...ot ex ceed a total length of 40 feet Any combination of rise and run may be used but must be constrained to the boundaries of this chart Foreachadditional 90 elbow reduce vent lengthby2feet Foreach ad...

Page 18: ...his minimum vertical rise a maximum horizontal run of 18 is permitted For longer horizontal runs the vertical rise must also increase The rise and run must be constrained to the boundries of the chart...

Page 19: ...connect the Dura Vent GS Snorkel Termination to the Estate flexible vent an Estate Snorkel Adaptor ESTD SNADPT is required 1 Attach the Estate Snorkel Adaptor to the Snorkel Terminal see Fig 19g 2 Ex...

Page 20: ...immediately upstream of the gas supply connection to the appliance Correct gas pressure requirement Natural Gas Propane Min Pressure 5 0 wc 12 5 wc For purpose of input adjustment Max Pressure 10 5 w...

Page 21: ...and set aside taking care not to damage them Remember the logs are extremely fragile Remove ember material and save for reuse 4 Disconnect gas supply line 5 Remove the two wing nuts under the firebox...

Page 22: ...ve the grate by removing four attach ment screws shown in Figure 23 Place the Platinum Bright Embers adjacent to the burner ports creating a channel as shown below Place the Glowing Embers randomly on...

Page 23: ...pins should have washers installed on them These washers are required to support the logs Place the coal chunk and the remaining logs as shown in Figures 23 26 Note Improper placement of logs may caus...

Page 24: ...lt the blower on its side and slide it past the left side of the gas valve Position the blower onto the studs located at the rear of the fireplace The studs must protrude through the front rubber grom...

Page 25: ...anual is not followed a fire may result causing PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE Unpack and inspect the Screen Door A flathead Phillips or a 2 Robertson screwdriver is required to insta...

Page 26: ...l your service technician or gas supplier 9 Turn gas control knob counter clockwise to On position 10 Turn HI LO burner control knob to desired setting 11 Close bottom grill and turn on the burner swi...

Page 27: ...o a desired setting As heat is required in the room the fireplace will turn on or off automatically Extend Shutdown To shutdown the appliance including the pilot partially depress and turn gas control...

Page 28: ...ASSEMBLY ESTF 3700 3 PANEL RIGHT OR LEFT SIDE 5098 403 4 PANEL BACK 5098 402 5 REPLACEMENT GLASS 5034 3 6 WINDOW GASKET KIT ESTD 50671 7 GLASS FRAME ESTG 17265 8 OVERLAY TRIM Standard ESTD STDO Radian...

Page 29: ...ASSEMBLY ESTF 3705 11 IGNITER 5016 5 12 ANDIRON ASSEMBLY ESTF 2822 13 VENTURI TUBE ASSEMBLY ESTF 501131A 14 VENTURI TUBE GASKET 5068 1012 15 MANIFOLD 5012 5 16 NG BURNER ORIFICE 39 5021 33 LP BURNER...

Page 30: ...he slots in the upper brackets see Fig 1 2 Fasten bottom louver to the hinge brackets at the bottom of the appli ance see Fig 2 Fig 1 This kit contains 1 Top Louver 1 Bottom Louver 6 8 x 1 2 sheet met...

Page 31: ...l Roof Thimble 1 4 1 2 Pipe Clamp Wall Termination Kit GASC WALKIT This vent kit is for use with these models The ESTATE and The ESTEEM fireplaces Please refer to the Installation Instructions provide...

Page 32: ...Sealant 1 Mastic 1 Roof Vent Terminal 1 Wall Roof Thimble 1 Support Sleeve 1 Storm Collar 2 Roof Brackets Roof Termination Kit ESTD ROTKIT This vent kit is for use with these models The ESTATE and The...

Page 33: ...and The ESTEEM fireplaces Please refer to the Installation Instructions provided with the appliance for proper venting installation This box contains 3 Pipe Spacer 2 8 x 1 2 sheet metal screws 8 10 x...

Page 34: ...Please refer to the Installation Instructions provided with the appliance for proper venting installation This box contains 10 4 Flex Vent 10 8 Flex Vent 1 4 Vent Connector 1 8 Vent Connector 1 Fires...

Page 35: ...l dans une maison pr fabriqu e mobile install e demeure si les r glements locaux le permettent Voir la notice du propri taire pour plus de d tails Cet appareil ne peut tre converti d autres gaz sauf s...

Page 36: ...36 Pacific Energy Fireplace Products Ltd PO Box 1060 Duncan B C V9L 3Y2 Phone 250 748 1184 Web site www pacificenergy net Printed in Canada fire parts com...

Reviews: