16
OPTIONAL VENTING
SIMPSON DURA-VENT - DIRECT VENT GS SYSTEM
The Estate Fireplace is also tested and certified for use with SIMPSON
DURA-VENT DIRECT VENT GS pipe. Kits for venting either through
the side wall or vertically through the roof are available from Simpson
Dura-Vent or your nearest Pacific Energy Authorized Dealer.
Before installing the Dura-Vent system, the installer should read the
instructions that accompany this appliance to ensure proper installa-
tion requirements are maintained.
CAUTION: UNDER NO CONDITION SHOULD COMBUSTIBLE
MATERIAL BE CLOSER THAN 1-3/4 INCHES FROM ANY VERTI-
CAL AND HORIZONTAL VENT SECTIONS OF THE SIMPSON
DURA-VENT DIRECT VENT GS SYSTEM.
Fig. # 19b
WALL TERMINATION
TOP VENTING
DURA-VENT GS
VERTICAL RISE
HORIZONTAL RUN
1’
2’
3’
4’
5’
1’
2’
3’
4’
5’-3"
MAX.
18"
31 1/2"
WALL TERMINATION
REAR VENTING
DURA-VENT GS
Fig. # 19a
VERTICAL RISE
HORIZONTAL RUN
Follow the vent pipe manufacturer's instructions for assembly and
installation. Allowable vent configurations are shown in Figures
#19a-d. For optimum performance and flame appearance, keep the
vent length to a minimum. A horizontal run of vent must have a 1/4"
rise for every 2 ft.of run towards the termination.
For Vent Restrictor installation, refer to the Pacific Energy Roof
Termination Venting and Vent Restrictor section (see Fig. #8f & 23).