MANUFACTURED (MOBILE) HOME
In some jurisdictions, the Estate Fireplace may be installed in
Manufactured Homes after the "first sale".
Consult local codes for
approval.
The fireplace must be fastened in place.
Install in accordance with the current standard CSA Z240.4 GAS
EQUIPPED RECREATIONAL VEHICLES AND MOBILE HOUSING
(in CANADA), and the Manufacturer's Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (in the U.S.A.).
GAS SUPPLY
Caution: The gas line should be installed by a qualified
service person in accordance with all building codes. This
section is intended as a guide for qualified technicians installing
this appliance. Consult local and/or national building codes
before proceeding.
The Estate comes equipped with a flexible connector with a 3/8"
N.P.T. male inlet for easy gas connection. This connector is attached
to the control valve under the burner assembly. Gas supply line may
enter the cabinet at the bottom left or right through the holes provided.
Proper gas line diameter must be used to assure proper operation. A
pressure test port (1/8" N.P.T. plugged tapping) must be provided for
checking gas pressure. The port must be located immediately
upstream of the gas supply connected to the appliance.
Correct gas pressure requirement:
Natural Gas
Propane
Min. Pressure
5.0" wc
11.0" wc
(For purpose of input adjustment)
Max. Pressure
10.5" wc
13.0" wc
Manifold Pressure
Maximum
3.8" wc
10.0" wc
Minimum
1.1" wc
6.2" wc
THERMOPILE
OPTIONAL
WALL SWITCH
INLET
PRESSURE
TEST POINT
MANIFOLD
PRESSURE
TEST POINT
PILOT FLAME
ADJUSTMENT
SCREW
WIRE LEAD
(PROVIDED)
SEE CHART
FOR PROPER
WIRE SIZE
OR
OR
GAS VALVE
WALL SWITCH OR THERMOSTAT
WARNING: Do not connect 110 - 120 VAC to the gas control valve
or control wiring system of this unit.
No electrical connection is required for the gas system operation. The
self-generating pilot provides current for the remote wall switch or wall
thermostat (not provided).
The installation of a wall switch allows for manual remote operation
of fireplace, and automatic operation with a wall thermostat. Use a
switch or thermostat rated for millivolts.
Position the wall switch or thermostat so that a minimum length of wire
is used the switch to the fireplace. Use appropriate wire gauge for
length. Connect the wall switch to the valve as shown in figure # 21.
The gas valve is prewired with a short wire lead for convenience.
Fig # 21
Recommended Thermostat Wire Size
Wire Size
Max. Length
14 ga. ........................... 100 ft.
16 ga. ............................ 60 ft.
18 ga. ............................ 40 ft.
20 ga. ............................ 25 ft.
22 ga. ............................ 18 ft.
OPTIONAL
WALL THERMOSTAT
(GASC.THERMO)
OPTIONAL
REMOTE CONTROL
(GASC.REMOTE)