INLET
PRESSURE
TEST POINT
MANIFOLD
PRESSURE
TEST POINT
PILOT FLAME
ADJUSTMENT
SCREW
OPTIONAL
WALL THERMOSTAT
(GASC.THERMO)
OPTIONAL
WALL SWITCH
OPTIONAL
REMOTE CONTROL
(GASC.REMOTE)
ROCKER
SWITCH
THERMOPILE
GAS
VALVE
Fig. # 18
Recommended Thermostat
Wire Size
Wire Size
Max. Length
14 ga ............................. 100 ft.
16 ga ............................. 60 ft.
18 ga ............................. 40 ft.
20 ga ............................. 25 ft.
22 ga ............................. 18 ft.
OPTIONAL WALL SWITCH OR
THERMOSTAT
WARNING: Do not connect electricity to the gas control
valve or control wiring system of this unit.
No electrical connection is required for this system operation.
The self-generating pilot provides current for the remote wall
switch or wall thermostat (not provided).
The installation of a wall switch allows for manual remote
operation of fireplace. Automatic operation with a wall
thermostat. Use only a switch or thermostat that is millivolt
rated.
Position the wall switch or thermostat so that a minimum
length of wire is used from the switch to the fireplace. Use
appropriate wire gauge for length of wire. Connect the wall
switch to the valve as shown in figure #18.