  The radiation exposure dosage received by personnel working with 

x-ray inspection equipment should not exceed those limits set by 
local regulations relating to ionizing radiation. 

 

  Adequate warning signs and symbols should be displayed in the 

vicinity of the XR 3500/3700 warning of possible x-ray exposure. 
Any warning lamps and signals should be checked prior to 
operating the XR 3500/3700. 

 

  The electrical circuits of the XR 3500/3700, although enclosed for 

operator protection, must be considered as a potential hazard. 
Strict observance of safety practices pertaining to operation and 
maintenance is essential.  Proper electrical grounding must always 
be used. 

 

  Before operating the XR 3500/3700, all personnel designated or 

authorized to operate the unit, as well as those supervising its 
operation, should have a full understanding of how it works. 
Additionally, they should be familiar with established radiation 
safety exposure practices sanctioned by the National Bureau of 
Standards Handbook, “X-ray Protection” HB93, pertaining to x-ray 
protection. 

 

  Service personnel should read this manual and be familiar with its 

contents before attempting to adjust or repair this equipment. 

 

 
 

2. 

Radiation Safety Information

 

 

Federal, State and Local Radiation Regulations (US ONLY)

 

 

This cabinet x-ray system was designed to conform to U.S. and Food 
and Drug Administration (FDA) requirements as stated in the Code of 
Federal Regulations, Title 21 (21CFR).  These requirements (often 
referred to as the CDRH or BRH regulations) govern the design and 
manufacture of all equipment that produces ionizing radiation.  Such 
equipment includes television sets and microwave ovens, as well as 
cabinet x-ray systems.  In fact, the maximum allowable radiation 
emission for cabinet x-ray systems is the same as that set for 
television sets and microwave ovens. 

Summary of Contents for XR 3700

Page 1: ...Ray Inspection System PN 8007 0542 120V PN 8007 0546 230V XR 3500 Real Time X Ray Inspection System PN 8007 0540 120V PN 8007 0544 230V This manual operation is for PACE s XR 3500 50kv unit and PACE...

Page 2: ...y Guidelines 6 XR 3700 Specifications 7 Features 7 System Operation 8 Set up 9 XR 3700 Initial Power up and Operational Test 10 XR 3700 Maintenance 11 XR 3700 Troubleshooting 12 Design Safety Standard...

Page 3: ...aware that the ionizing radiation x rays can constitute a distinct hazard if not employed in strict accordance with instructions provided in this manual for maximum operator safety Exposure to excessi...

Page 4: ...e a full understanding of how it works Additionally they should be familiar with established radiation safety exposure practices sanctioned by the National Bureau of Standards Handbook X ray Protectio...

Page 5: ...d constraints regarding the modification of x ray systems conforming to 21CFR mentioned above Typically an x ray system must be registered with the appropriate state agency by the physical possessor o...

Page 6: ...ount of radiation being emitted by the machine is less than 0 5mR hour We recommend performing a radiation survey Following initial installation before placing the x ray system into service Whenever t...

Page 7: ...PCB size 760mm x unlimited mm 30 x unlimited Focal spot 0 2mm 0 008 Focal spot to image plane distance 124mm 4 875 Adjustments Live or Capture video signal Frame averaging up to 32000 frames Video Ga...

Page 8: ...etermine the presence and degree of interlayer shifts At the onset of either conventional or small hole drilling inspection is used to qualify hole to pad alignment In addition to enhancing product qu...

Page 9: ...e bnc cable should be connected to the composite video input on the video monitor a bnc to RCA converter might be needed The power cord should be connected to a properly grounded 120 VAC power supply...

Page 10: ...as been returned to the off position The power light should blinks when the key switch is on and the cover lock is disengaged Then when the cover lock is engaged the power light turns steady 2 Make su...

Page 11: ...eo processor included with this system is preset to 8 frames averaging Averaging makes the x ray image less grainy and can be adjusted to improve image quality but with an increase in motion lag 8 Ima...

Page 12: ...t the system Power The power category covers all problems that include lack of power to a component or to the full system Power problems would include The system not powering up The x ray controller s...

Page 13: ...r Devices and Radiological Health Branch of the FDA as an Analytical X ray System As registered the system has a number of safety features provided to minimize any x ray scatter reaching the operator...

Page 14: ...ecific regulations regarding the monitoring of possible radiation leakage of industrial x ray cabinets are determined by the individual state or country There are a number of measures which can be tak...

Page 15: ...ption repair or replace any defective products at its facility or other location approved by it at no charge to user or provides parts without charge for installation by the user in the field at user...

Page 16: ...orporated to obtain the latest specifications The following are trademarks and or service marks of PACE Incorporated MD USA INSTACAL FUMEFLO HEATWISE PACEWORLDWIDE PERMAGROUND POWERMODULE and TEMPWISE...

Reviews: