background image

©2022 PACE Inc., Vass, North Carolina, All Rights Reserved                                                           Page 7 
https://paceworldwide.com/ 
 

show "Lo" and the stored limit. Choose one of the following: 

 

Press and release the Program Key ( ) to keep the stored Low Temperature Limit. 

 

Adjust the stored Lo Temperature Limit using the keypad. (

 

Press and release the Program Key ( ) to proceed to the next step. 

 

The full allowable temperature range of the ST35 is between 38°C (100°F) and 482°C (900°F).  The Low 
Temperature Limit cannot be adjusted higher than the High Temperature Limit.  These limits control how high or 
low the Set Temperature can be adjusted to during normal operation. 

 

Automatic Setback Timer 

 
To preserve tip life and save energy, the system can automatically adjust the tip temperature to 177°C (350°F) 
after a selectable period of inactivity (factory setting of 30 minutes). There are 3 ways to exit Temperature 
Setback; pressing the Scroll Up or Scroll Down keys (

), flipping the power switch off then on again, or 

holding the tip against a damp sponge.  Upon exit of the Temperature Setback, the unit will resume normal 
operations and the handpiece heat back up to the Set Temperature. 

 

7.  The display now shows the stored Automatic Setback time as "S-X" (x=0 thru 9). 

Time is shown as tens of minutes (e.g., "S-3" equals 30 minutes). A display of "S-0" 
indicates that Setback is disabled. Choose one of the following: 

 

Press and release the Program Key ( ) to keep the currently stored 
Temperature Setback time. 

 

Adjust the stored Temperature Setback value using keypad. (

 

Press and release the Program Key ( ) to proceed to the next step. 

 

AutoOff 

 
What is AutoOff?  When enabled, the AutoOff safety feature turns off the power to the handpiece after a pre-
selected time (between 10- 90 minutes) from the system entering Temperature Setback. When the system has 
entered Temperature Setback, a timer within the system circuitry will start running. 
 
If any key is pressed during the selected time out period, the AutoOff and Setback timers are reset. The system 
will return to normal operation. At the end of the time out period, the system will enter Auto Off. Power is turned 
off to the heater and the display will show a flashing “OFF”.  Exiting Auto Off: Auto Off can be exited; returning to 
normal operation by pressing and releasing a Key (any of the 3 keys 

), or by turning the Power Switch 

OFF (“0”) and then back ON (“1”). 

 

8.  The display now shows the stored Auto Off time as "AOx" (x=0 thru 9). Time is 

shown as tens of minutes (e.g., "AO8" equals 80 minutes). A display of "AO0" 
indicates that Auto Off is disabled. Choose one of the following:  

 

Press and release the Program Key ( ) to keep the currently stored Auto 
Off time. 

 

Adjust the Auto Off value using the keypad. (

 

Press and release the Program Key ( ) to proceed to the next step. 

 
 
 
 

Exiting Set-Up Mode 

 

Summary of Contents for ST35 w/PS-90 Iron

Page 1: ...e Manual for ST35 Soldering System Manual 5050 0606 Rev Date 6 14 2022 This manual applies to Model Firmware Revision Required Power Part Number ST35 w PS 90 Iron 1 2 120 VAC 8007 0599 ST35 w PS 90 Ir...

Page 2: ...tion 3 Operation 4 Tip Offset 4 LED Display Normal Operation 4 Digital Control Indicator LED 4 Temperature Adjustment Display Mode 5 Default Factory Settings 5 Customizing Your System 5 Entering Set U...

Page 3: ...t or exceed the requirements for electrostatic discharge set forth by ANSI ESD S20 20 Compliance with both standards is ensured by testing up to 50 MHz using the methodology described in ANSI ESD S13...

Page 4: ...s 5 Exercise proper precautions when using chemicals e g solder paste or flux Refer to the Material Safety Data Sheet MSDS supplied with each chemical and adhere to all safety precautions recommended...

Page 5: ...included hardware Assembly instructions are enclosed with each Tip Tool Stand Handpiece Connection The ST35 is designed to work with the SensaTemp PS 90 Soldering Iron or any other of the SensaTemp ha...

Page 6: ...sting offset it is recommended to first check the actual temperature of the tip using a Tip Temperature Monitor To adjust the temperature offset hold the Program Key down for 5 seconds The display wil...

Page 7: ...t Display Mode The display will show the following when adjusting the desired Set Tip Temperature 1 The Set Tip Temperature 2 HiL High Temperature Limit when adjusting the set tip temperature and the...

Page 8: ...rs repeat steps 1 2 and enter the correct Password Once the LED Display reads P Choose one of the following options Press the Program Key to keep the current password even if there is no password and...

Page 9: ...display of S 0 indicates that Setback is disabled Choose one of the following Press and release the Program Key to keep the currently stored Temperature Setback time Adjust the stored Temperature Setb...

Page 10: ...ect handpiece and heater element replace as needed OSE Open Sensor Error Unit is unable to sense the sensor from the handpiece Make sure handpiece is connected Inspect handpiece and heater element for...

Page 11: ...user s expense and risk User will be responsible for all costs of shipping equipment to Seller or other location for warranty service EXCEPT FOR THE REMEDY ABOVE DESCRIBED UNLESS OTHERWISE REQUIRED B...