background image

©2022 PACE Inc., Vass, North Carolina, All Rights Reserved                                                           Page 4 
https://paceworldwide.com/ 
 

Operation 

 

1.  Ensure the Set-Up procedure has been performed. Check the following:  

 

Handpiece connection to the power source. 

 

Proper Tip is installed in handpiece.  

 

Power cord is connected to both an appropriate 
AC supply and the ST35 unit. 

2.  Turn the Power Switch On ("I"). 

3.  After a brief start-up sequence, the Set Temperature 

will be displayed. 

4.  Adjust the tip temperature by pressing and holding 

Scroll Up ( ) Key or Scroll Down (

) key. Observe the 

display as the Set Temperature increases first in 
increments of 1° and then in increments of 10°. When 
the desired temperature is reached, release the key. 

5. 

NOTE:

 The Set Temperature can be adjusted only 

within the defined temperature limits. If the upper limit has been reached, the display will read “HiL”; if 
the lower limit is reached, the display will read “OFF”. Temperature limits can be adjusted in the Set-Up 
menu. 

 
 

Tip Offset 

 

Differences between the temperature settings and true tip temperatures are negligible when using Thru-Hole, 
single point soldering tips.  With any heating system however, True Tip Temperatures can differ greatly from 
temperature settings when using larger SMT soldering tips.  Before adjusting offset, it is recommended to first 
check the actual temperature of the tip using a Tip Temperature Monitor. 
 
To adjust the temperature offset, hold the Program Key ( )  down for 5 seconds. The display will change to 
show “000”.  If the unit already has a Tip Offset than it will be shown in place of “000”. Use the keypad (

) to 

increase the temperature offset up to 83°C (150°F) hotter.  When finished press the Program Key ( ) to return 
to normal operation or, after 5 seconds of inactivity, the system will return to normal operation on its own. 
 
 

LED Display - Normal Operation 

 

The LED Display provides a 3-digit display of information. The display will show different things such as: 
 

1.  "888" on initial power up to ensure that all sections of the display are working. 

2.  The software version of the installed microprocessor (e.g., "1-9") for 2 seconds after the "888" is 

displayed. 

3.  Actual temperature of the connected handpiece, during normal operation. 

4.  The displayed temperature will begin blinking (the indicator LED will also turn Amber) when the unit has 

gone into Temperature SetBack. 

5.  "OFF" with stable display when the temperature set point has been adjusted beyond the Lower 

Temperature Limit. 

6.  "OFF" with blinking display when the unit has entered AutoOff mode. Refer to page 7 for more 

information. 

Error messages "OSE" or “OCE” will appear if a system fault is detected. Refer to the "Corrective 
Maintenance" portion of this manual. 

 

Digital Control Indicator LED 

Summary of Contents for ST35 w/PS-90 Iron

Page 1: ...e Manual for ST35 Soldering System Manual 5050 0606 Rev Date 6 14 2022 This manual applies to Model Firmware Revision Required Power Part Number ST35 w PS 90 Iron 1 2 120 VAC 8007 0599 ST35 w PS 90 Ir...

Page 2: ...tion 3 Operation 4 Tip Offset 4 LED Display Normal Operation 4 Digital Control Indicator LED 4 Temperature Adjustment Display Mode 5 Default Factory Settings 5 Customizing Your System 5 Entering Set U...

Page 3: ...t or exceed the requirements for electrostatic discharge set forth by ANSI ESD S20 20 Compliance with both standards is ensured by testing up to 50 MHz using the methodology described in ANSI ESD S13...

Page 4: ...s 5 Exercise proper precautions when using chemicals e g solder paste or flux Refer to the Material Safety Data Sheet MSDS supplied with each chemical and adhere to all safety precautions recommended...

Page 5: ...included hardware Assembly instructions are enclosed with each Tip Tool Stand Handpiece Connection The ST35 is designed to work with the SensaTemp PS 90 Soldering Iron or any other of the SensaTemp ha...

Page 6: ...sting offset it is recommended to first check the actual temperature of the tip using a Tip Temperature Monitor To adjust the temperature offset hold the Program Key down for 5 seconds The display wil...

Page 7: ...t Display Mode The display will show the following when adjusting the desired Set Tip Temperature 1 The Set Tip Temperature 2 HiL High Temperature Limit when adjusting the set tip temperature and the...

Page 8: ...rs repeat steps 1 2 and enter the correct Password Once the LED Display reads P Choose one of the following options Press the Program Key to keep the current password even if there is no password and...

Page 9: ...display of S 0 indicates that Setback is disabled Choose one of the following Press and release the Program Key to keep the currently stored Temperature Setback time Adjust the stored Temperature Setb...

Page 10: ...ect handpiece and heater element replace as needed OSE Open Sensor Error Unit is unable to sense the sensor from the handpiece Make sure handpiece is connected Inspect handpiece and heater element for...

Page 11: ...user s expense and risk User will be responsible for all costs of shipping equipment to Seller or other location for warranty service EXCEPT FOR THE REMEDY ABOVE DESCRIBED UNLESS OTHERWISE REQUIRED B...