Set up the ST35 system by doing the following. 

 

1.  Remove the unit from its shipping container. Store the shipping container(s) in a convenient location. 

Reuse of these containers will prevent damage if you ship or store the system. 

 

2.  Place the unit on a convenient workbench. 

 

3.  Ensure the POWER Switch (located on power source front panel) is in the "OFF" or "0" position. 

 

4.  Inspect all system components, check for shipping damage, and ensure that all purchased components 

(standard and optional) are present. 

 

5.  Assemble Tip & Tool Stands. Attach to the power source if desired using included hardware. Assembly 

instructions are enclosed with each Tip & Tool Stand. 

 
 

Handpiece Connection 

 
The ST35 is designed to work with the SensaTemp PS-90 Soldering Iron or any other of the SensaTemp hand 
tools that do not need air pressure or vacuum to function. 

Caution:

 Using handpieces from other product lines 

(e.g., IntelliHeat, AccuDrive, HeatWise) may result in damage to your new equipment. 

 

Connect the handpiece connector to the Power Receptacle in the following manner. 
 

1.  Align guide on connector with slot on power receptacle. 

2.  Insert connector into power receptacle. 

3.  Turn the connector housing clockwise to lock in place. 

 
 
 

System Power 

 

1.  Insert the female end of the power cord into the AC Power Receptacle on the rear panel of the power 

source. 

2.  Plug the prong end (male end) of the power cord into an appropriate, grounded AC supply receptacle. 

 
 
 
 

Setup and Operation 

 

Summary of Contents for ST35 w/PS-90 Iron

Page 1: ...e Manual for ST35 Soldering System Manual 5050 0606 Rev Date 6 14 2022 This manual applies to Model Firmware Revision Required Power Part Number ST35 w PS 90 Iron 1 2 120 VAC 8007 0599 ST35 w PS 90 Ir...

Page 2: ...tion 3 Operation 4 Tip Offset 4 LED Display Normal Operation 4 Digital Control Indicator LED 4 Temperature Adjustment Display Mode 5 Default Factory Settings 5 Customizing Your System 5 Entering Set U...

Page 3: ...t or exceed the requirements for electrostatic discharge set forth by ANSI ESD S20 20 Compliance with both standards is ensured by testing up to 50 MHz using the methodology described in ANSI ESD S13...

Page 4: ...s 5 Exercise proper precautions when using chemicals e g solder paste or flux Refer to the Material Safety Data Sheet MSDS supplied with each chemical and adhere to all safety precautions recommended...

Page 5: ...included hardware Assembly instructions are enclosed with each Tip Tool Stand Handpiece Connection The ST35 is designed to work with the SensaTemp PS 90 Soldering Iron or any other of the SensaTemp ha...

Page 6: ...sting offset it is recommended to first check the actual temperature of the tip using a Tip Temperature Monitor To adjust the temperature offset hold the Program Key down for 5 seconds The display wil...

Page 7: ...t Display Mode The display will show the following when adjusting the desired Set Tip Temperature 1 The Set Tip Temperature 2 HiL High Temperature Limit when adjusting the set tip temperature and the...

Page 8: ...rs repeat steps 1 2 and enter the correct Password Once the LED Display reads P Choose one of the following options Press the Program Key to keep the current password even if there is no password and...

Page 9: ...display of S 0 indicates that Setback is disabled Choose one of the following Press and release the Program Key to keep the currently stored Temperature Setback time Adjust the stored Temperature Setb...

Page 10: ...ect handpiece and heater element replace as needed OSE Open Sensor Error Unit is unable to sense the sensor from the handpiece Make sure handpiece is connected Inspect handpiece and heater element for...

Page 11: ...user s expense and risk User will be responsible for all costs of shipping equipment to Seller or other location for warranty service EXCEPT FOR THE REMEDY ABOVE DESCRIBED UNLESS OTHERWISE REQUIRED B...

Reviews: