background image

©2022 PACE Inc., Vass, North Carolina, All Rights Reserved                                                           Page 5 
https://paceworldwide.com/ 
 

 

The colored LED on the power source front panel indicates when the handpiece is 
heating, has reached the set temperature, or if a fault has occurred. 
 

LED Full On Red

 – A fault has occurred such as nothing is plugged into the 

Power Receptacle on the front of the unit or the Heater Element of the connected 
tool has an issue. Check installation of Heater Element on the handpiece as well 
as the handpiece’s connection to the front panel.  

LED Full On Green

 – The attached soldering tool has reached the Set 

Temperature. 

LED Full On Amber 

– The heater in the connected handpiece is functioning and 

in process of heating up to the Set Temperature or may be cooling down to the 
SetBack Temperature. 

LED Off 

- Unit is not turned on or is in Auto ShutOff.  

 

Temperature Adjustment Display Mode 

 

The display will show the following when adjusting the desired Set Tip Temperature. 
 

1.  The Set Tip Temperature. 

2.  "HiL" (High Temperature Limit) when adjusting the set tip temperature and the 

maximum allowable temperature is exceeded. Refer to the "Set-Up Mode" portion 
of this manual.  

3.  "OFF" (Low Temperature Limit) when adjusting the set tip temperature and the 

minimum allowable temperature is exceeded. Refer to the "Set-Up Mode" portion 
of this manual.   

 

 

Default Factory Settings 

 
Your new ST35 is equipped with several features which may be adjusted by the user. Listed below are the 
default settings of each. To learn about any of these features, refer to the applicable section of the “Customizing 
Your System” in this manual. 
 

Feature 

Factory Setting 

Password 

None Entered 

Default Temperature Scale 

(°C/°F) 

°F for 115 VAC Systems 

°C for 230 VAC Systems 

“HI” Temperature Limit 

427 °C (800 °F) 

“LO” Temperature Limit 

260 °C (500 °F) 

SetBack Timer 

Enabled, 30 minutes 

Auto Off 

Enabled, 60 minutes 

Set Temperature 

371 °C (700 °F) 

Tip Offset 

0 °C (0 °F) 

 

 
 
 
 
 

Customizing Your System 

 

Summary of Contents for ST35 w/PS-90 Iron

Page 1: ...e Manual for ST35 Soldering System Manual 5050 0606 Rev Date 6 14 2022 This manual applies to Model Firmware Revision Required Power Part Number ST35 w PS 90 Iron 1 2 120 VAC 8007 0599 ST35 w PS 90 Ir...

Page 2: ...tion 3 Operation 4 Tip Offset 4 LED Display Normal Operation 4 Digital Control Indicator LED 4 Temperature Adjustment Display Mode 5 Default Factory Settings 5 Customizing Your System 5 Entering Set U...

Page 3: ...t or exceed the requirements for electrostatic discharge set forth by ANSI ESD S20 20 Compliance with both standards is ensured by testing up to 50 MHz using the methodology described in ANSI ESD S13...

Page 4: ...s 5 Exercise proper precautions when using chemicals e g solder paste or flux Refer to the Material Safety Data Sheet MSDS supplied with each chemical and adhere to all safety precautions recommended...

Page 5: ...included hardware Assembly instructions are enclosed with each Tip Tool Stand Handpiece Connection The ST35 is designed to work with the SensaTemp PS 90 Soldering Iron or any other of the SensaTemp ha...

Page 6: ...sting offset it is recommended to first check the actual temperature of the tip using a Tip Temperature Monitor To adjust the temperature offset hold the Program Key down for 5 seconds The display wil...

Page 7: ...t Display Mode The display will show the following when adjusting the desired Set Tip Temperature 1 The Set Tip Temperature 2 HiL High Temperature Limit when adjusting the set tip temperature and the...

Page 8: ...rs repeat steps 1 2 and enter the correct Password Once the LED Display reads P Choose one of the following options Press the Program Key to keep the current password even if there is no password and...

Page 9: ...display of S 0 indicates that Setback is disabled Choose one of the following Press and release the Program Key to keep the currently stored Temperature Setback time Adjust the stored Temperature Setb...

Page 10: ...ect handpiece and heater element replace as needed OSE Open Sensor Error Unit is unable to sense the sensor from the handpiece Make sure handpiece is connected Inspect handpiece and heater element for...

Page 11: ...user s expense and risk User will be responsible for all costs of shipping equipment to Seller or other location for warranty service EXCEPT FOR THE REMEDY ABOVE DESCRIBED UNLESS OTHERWISE REQUIRED B...

Reviews: