Pace 8007-0387 Operation And Maintenance Manual Download Page 4

System Operations Manual, Rev B 

www.paceworldwide.com

 

Page 4 of 21 

Safety Guidelines 

 

English Language Safety Guidelines:  

The following are safety precautions that personnel must 

understand and follow when using or servicing this product. 
 

1.

  POTENTIAL SHOCK HAZARD - 

Repair procedures on PACE products should be performed 

by Qualified Service Personnel only.  Line voltage parts may be exposed when the 
equipment is disassembled.  Service personnel must avoid contact with these parts when 
troubleshooting the product. 

2.  To prevent personnel injury, adhere to safety guidelines in accordance with OSHA and other 

applicable safety standards.  

3.  SensaTemp handpiece heaters and installed tips are hot when the handpiece is powered on 

and for a period of time after power off.  

DO NOT

 touch either the heater or the tip.  Severe 

burns may result. 

4.  PACE Tip & Tool Stands and handpiece cubbies are designed specifically for use with the 

associated handpiece and houses it in a manner that protects the user from accidental burns.  
Always store the handpiece in its holder.  Be sure to place the handpiece in its holder after 
use and allow for cooling before storing.  

5.  Always use PACE systems in a well ventilated area.  A fume extraction system such as those 

available from PACE are highly recommended to help protect personnel from solder flux 
fumes. 

6.  Exercise proper precautions when using chemicals (e.g., solder paste).  Refer to the Material 

Safety Data Sheet (MSDS) supplied with each chemical and adhere to all safety precautions 
recommended by the manufacturer. 

 

Directives de Sécurité, Française Langue:

  Les précautions suivantes, sont celles que le personnel 

doit comprendre et suivre lorsqu'il utilise, effectue la maintenance ou se sert d'un produit PACE. 

 

1.

  Danger potentiel de choc èlectrique - 

Les procédures de réparation sur les produits PACE 

doivent être effectuées seulement par du personnel qualifié.  Des parties de l'équipement 
désassemblées peuvent être sous tension.  Le personnel de maintenance doit éviter tout 
contact avec ces parties en réparant le produit. 

2.  Pour prévenir tout préjudice, le personnel adhère au guide de sécurité en accord avec OSHA 

(équivalent à des normes françaises de sécurité) et d'autres standards de sécurité applicable. 

3.  La mise sous tension des outils SensaTemp comporte des éléments chauffants (buse).  Ces 

derniers, gardent la chaleur même après la mise hors tension pendant un certain temps.  

Ne 

pas

 toucher les parties chaudes aux extrémités des outils.  Des brûlures sévères peuvent en 

résulter. 

4.  Les outils PACE et leurs pannes ainsi que le support sont dessinés de manière spécifique 

afin de protéger l'utilisateur/opérateur de brûlures accidentelles.  Reposer toujours les outils 
après chaque utilisation dans leurs étuis/supports afin de permettre leur refroidissement. 

5.  Utiliser toujours les stations Pace dans unlieu bien ventilé.  Des extracteurs de fumée Pace 

sont hautement recommandés pour protéger votre personnel des vapeurs de soudure/flux. 

6.  Prenez les mesures nécessaires quand vous utilisez des produits (ex: solder paste) chimiques.  

Reportez-vous au document (fiche technique/sécurité) du fabricant fourni avec chaque produit.  
Respectez toutes les procédures de sécurité recommandées par le constructeur. 

 

Sicherheit Korrekturlinien, Deutsche Sprache:  

Die nachfolgenden Sicherheitsvorschriften sollten vom 

Bedien- un Servicepersonal verstanden und befolgt werden. 

 

1. 

Entladung spannungsfuehrender Teile -

 Reparaturen an PACE Produkten sollten nur von 

qualifizierten Personal durchgefuehrt werden. Spannungsfuehrende Teile koennen sich bei 
gezogenen Netzstecker entladen. Servicepersonal muss den Kontakt dieser Teile vermeiden.  

Summary of Contents for 8007-0387

Page 1: ...HeatWise TW 100 TempWise Soldering Systems 5050 0512 Rev B PRM Voltage Part Number HW 100 HEATWISE System 115 VAC 8007 0387 HW 100 HEATWISE System 230 VAC 8007 0388 TW 100 TEMPWISE System 115 VAC 800...

Page 2: ...tion 8 Operation 9 Definitions 9 HW 100 System 9 TW 100 System 10 LED Display 11 Temperature Adjust Mode 11 Temperature Setback Mode 11 Auto Off Mode 12 Using InstaCal 12 Programming Your System 13 En...

Page 3: ...Max 97 127 VAC 50 60 Hz 80 W Max or 197 253 VAC 50 60 Hz 80 W Max Dimensions 184mm H x 107mm W x 122mm D 7 25 H x 4 2 W x 4 8 D 184mm H x 107mm W x 122mm D 7 25 H x 4 2 W x 4 8 D Tip Tool Stand Dimen...

Page 4: ...sert d un produit PACE 1 Danger potentiel de choc lectrique Les proc dures de r paration sur les produits PACE doivent tre effectu es seulement par du personnel qualifi Des parties de l quipement d sa...

Page 5: ...all OSHA e agli altri Standard di Sicurezza applicabili 3 Le resistenze PACE Sensatemp e le punte installate sono calde quando la stazione accesa e per un periodo successivo allo spegnimento Non tocc...

Page 6: ...rte Est seguro de poner la herramienta en su soporte despu s del uso y permita que la herramienta enfr e antes de guardar 5 Siempre use sistemas de PACE en una rea bien ventilada Un sistema de extracc...

Page 7: ...r a workbench or shelf See Figure 5 It is important to note that the Interlock can be mounted on either side of the power source In the examples below the Tool Stand has been mounted on the left of th...

Page 8: ...extraction equipment is recommended Tip Cartridge Installation Tip cartridges are fitted with a key lock device This feature ensures that tip cartridges are held firmly in position and will maintain...

Page 9: ...hat will independently set back the Set Tip Temperature to 177 C 350 F after a user selected or preset period of handpiece inactivity HW 100 Heat Wise System The HW 100 requires the use of a Power Mod...

Page 10: ...Adjust the temperature by pressing and holding Scroll Up Key or Scroll Down key Observe the display as the Set Temperature increases first in increments of 5 then in increments of 10 When the desired...

Page 11: ...ture is exceeded Refer to the Programming Your System portion of this manual 3 OFF Low Temperature Limit when adjusting the set tip temperature and the minimum allowable temperature is exceeded Refer...

Page 12: ...d releasing any key on the front panel or or 2 By turning the Power Switch OFF 0 and then back ON l Using the InstaCal Feature The TW 100 features InstaCal calibration InstaCal allows the user to cali...

Page 13: ...time out period Enable or disable the Auto Off feature and adjust the time out period Enable or disable the Calibration mode The following instructions should be performed to familiarize the operator...

Page 14: ...wn as tens of minutes e g S 3 equals 30 minutes A display of S 0 indicates that Setback is disabled Choose one of the following a Press and release the Program Key to keep the currently stored Tempera...

Page 15: ...e OFF Temperature Setback Enabled 30 minutes Auto Off Enabled 60 minutes Cartridge Offset Zero Table 1 Factory Settings InstaCal Adjustment In most cases the InstaCal calibration will closely match yo...

Page 16: ...the up and down keys adjust the ICA offset as needed 4 Press the program key to exit the ICA menu and resume normal operation PACE does not recommend modifying the ICA offset to compensate for tip ge...

Page 17: ...0023 P1 1 8 90 Degree Chisel Extended 1124 0024 P1 1 16 30 Degree Bevel 1124 0025 P1 1 16 Conical Sharp Extended 1124 0026 P1 1 16 Chisel Bent 30 Degrees 1124 0027 P1 3 128 Conical Sharp Extended 1124...

Page 18: ...o be attached to the Power source Shown with HW 100 1335 0251 P1 Bench Mounting Bracket for HW 100 TW 100 1321 0639 P1 TC 100 Handpiece Tip cartridge not included 6010 0132 P1 Replacement TC 100 cord...

Page 19: ...ng may need to be replaced over time To replace the O ring follow the procedure below 1 Disconnect the TC 100 from the power source 2 Remove the tip cartridge 3 Unscrew the cap from the back of the TC...

Page 20: ...lusions and limitations herein apply to all persons and entities SELLER MAKES NO OTHER WARRANTY EXPRESS OR IMPLIED AND MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Seller w...

Page 21: ...MODULE and TEMPWISE The following are registered trademarks and or service marks of PACE Incorporated Laurel Maryland U S A ARM EVAC FLO D SODR MINIWAVE PACE SENSATEMP SNAP VAC SODRTEK SODR X TRACTOR...

Reviews: