System Operations Manual, Rev B
www.paceworldwide.com
Page 3 of 21
Packing Contents
Description HW
100
System
TW 100 System
Power Supply
HW 100
TW 100
Handpiece TC
100
(6010-0132-P1)
TC 100
(6010-0132-P1)
Tip & Tool Stand
1257-0258-P1
1257-0258-P1
Power Module 5
1207-0362-01-P1
N/A
Power Module 6
1207-0362-03-P1
N/A
Power Module 7
1207-0362-05-P1
N/A
InstaCal Module
N/A
1207-0364-P1
Hot Grip Removal Pad
1100-0307-P1
1100-0307-P1
Specifications
Specification HW
100 TW
100
Power
Requirements
97-127 VAC 50/60 Hz, 80 W Max
or
197-253 VAC 50/60 Hz, 80 W Max
97-127 VAC 50/60 Hz, 80 W Max
or
197-253 VAC 50/60 Hz, 80 W Max
Dimensions
184mm H x 107mm W x 122mm D
(7.25” H x 4.2” W x 4.8” D)
184mm H x 107mm W x 122mm D
(7.25” H x 4.2” W x 4.8” D)
Tip & Tool Stand
Dimensions
71mm H x 88mm W x 195 mm D
(2.8” H x 3.5” W x 7.7” D)
71mm H x 88mm W x 195 mm D
(2.8” H x 3.5” W x 7.7” D)
Weight
1.6 Kgs (3.5 lbs)
1.6 Kgs (3.5 lbs)
TC 100 Handpiece
Weight
88.2 g (3.1 oz)
88.2 g (3.1 oz)
Tip to Ground
Resistance
< 2 Ohms
< 2 Ohms
Temperature
Stability
/- 5
°
C (9
°
F), idle tip
temperature
/- 5
°
C (9
°
F), idle tip
temperature
Absolute
Temperature
Accuracy
N/A
/- 15
°
C (27
°
F)
Heat
Level/Temperature
Range
260
°
C - 425
°
C (500
°
F – 800
°
F)
Available Power Module Heat Levels: 5,
5.5, 6, 6.5, 7, 7.5, & 8
260
°
C - 425
°
C (500
°
F – 800
°
F)
Figure 1: HW 100 and TW 100 Systems