PENTA-7500S Belt Grinder
I
NSTRUCTION
M
ANUAL
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
▲
3601 E. 34th St. Tucson, AZ 85713 USA Tel. +1 520-882-6598 Fax +1 520-882-6599 email: [email protected] Web: https://www.metallographic.com
Please read this instruction manual carefully and follow all installation, operating and safety guidelines.
10
Problem
Cause
Solution
No water supply
1. Water valve closed
2. Water tube is extremely bent
1.Open the water valve
2.Straighten out water tube
Water leaking
1. Door is not closed
completely
2. Drain hose plugged
3. Unit not tilted properly
4. Water flow is too high
1. Ensure nothing is blocking
door from closing
2. Clean drain hose
3. Adjust front feet to slope
towards drain hole
4. Reduce water flow to allow
system to drain properly
6.0 Trouble Shooting
More extensive troubleshooting, repair guides, videos, and parts lists are provided
online at metallographic.com.
Feel free to contact a PACE Representative at +1(520) 882-6598