MODEL MMC200
MULTI-MATERIAL CUTTER
MMC200 SPECIFICATIONS
Maximum cut length.............99,999" (or 99,999 cm)
@ +/- 1% accuracy
Minimum cut length.............. 0.100" (.25cm) or less
@ +/- 0.02"(.05cm) accuracy
Maximum material size:
Tubing.......................0.625" (5/8") OD (ø1.58 cm)
Flat Material...............................3.94" (10 cm) wide
Wire......................10 AWG (.040cm) solid copper
Tolerance........................................... 1% or better
(dependent on material and feeding system)
Batching…………up to 99 programmable batches
Power Requirements
Electrical
………....…..
.115Vac or 230Vac (+/-10%)
Consumption
……………………………...…
200W
Compressed air
………………...……..
40 to 90PSI
Feed rates……………....10 selectable feed rates
Ordering Information
AR7161...................................................115V 60Hz
AR7162.................220/240V, 50Hz, European plug
Optional Accessories
AR3801 (DE400)....................... Vertical Dereeler
AR0170 (DE700).................Compensatting dereeler
AR6201 (APF100)..............................Prefeeder(115V)
AR6202 (APF100)..............................Prefeeder(230V)
TR1413............................High speed steel lower blade
TR1415............................High speed steel upper
blade
Replacement Parts
IR1205...........Replacement guillotine(upper) blade
IR1203.................Replacement anvil (lower) blade
PR0655...........................................4A fuse (115V)
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS
WARNING: DO NOT OPERATE TOOL UNTIL
YOU HAVE READ THOROUGHLY, AND UNDER-
STAND COMPLETELY, ALL INSTRUCTIONS,
RULES, ETC. ON THIS PAGE, AND IN THE
OPERATING MANUAL. WHEN USING ELEC-
TRIC TOOLS, BASIC SAFETY PRECAUTIONS
SHOULD ALWAYS BE FOLLOWED TO RE-
DUCE RISK OF FIRE, ELECTRIC SHOCK, AND
PERSONAL INJURY, INCLUDING THE FOL-
LOWING:
GROUNDING INSTRUCTIONS
In the event of a malfunction or breakdown, ground-
ing provides a path of least resistance for electric
current to reduce the risk of electric shock. This
tool is equipped with an electric cord having an
equipment-grounding conductor and a grounding
plug. The plug must be plugged into a matching
outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
Feedrate # inches/sec cm/sec
0
6.6
16.8
1
9.9
25.2
2
13.2
33.6
3
16.6
42.1
4
19.9
50.5
5
26.5
67.3
6
29.8
75.7
7
33.1
84.1
8
36.4
92.5
9
39.7
100.9
MMC200 Feed belt speeds
Feedrate # / Length
1"
2"
6"
10"
20"
100"
0
5,792
4,129
2,009
1,327
718
154
1
6,058
4,411
2,571
1,935
1,196
295
2
6,963
5,354
3,363
2,613
1,679
435
3
8,042
6,495
4,359
3,410
2,207
578
4
8,366
6,843
4,689
3,781
2,549
707
5
8,533
7,024
4,858
3,992
2,801
827
6
8,731
7,240
5,062
4,192
3,032
943
7
8,822
7,339
5,157
4,279
3,180
1,049
8
8,822
7,339
5,157
4,279
3,237
1,140
9
8,822
7,339
5,157
4,279
3,251
1,183
Production rates (in pieces per hour) at various feedrates