26
with initial digits – 0592,17900, 2,8, First input 44310# 45310#(refer4.12.2); then input
43010592#, 430217900#,43032#,43048#
4.13 Private Password Setting/Clearing
4.13.1 Set Private Password for User
Format: 5 UV WXYZ L#
Explanation: UV: private password sequence number, UV= 01 - 99,(not Extension No.)
WXYZ: 4 digits password, can’t less 4 digits
L: service class of private password (refer to 4.16.2)
Description: Set the No. UV private password for one user.
Example: Set No.08 password 1234 for Mr. David, the class is 1 and No.30 is password 8886 for
Mrs. Linda, the class is 2,then input 50812341#,53088862#
1. How to use private password refer to 5.10
2. This function better work for dialing-out class 0.
4.13.2 Clear Certain Private Password
Format: 5 UV #
Explanation: UV : private password sequence number,
Description: Clear No.UV private password.
4.13.3 Clear All Private Passwords
Format: 5 0 0 #
Description: Clear All private password.
4.14 Exts. Using C.O.Lines Access
4.14.1 Assign Exts. Outgoing to Certain C.O.Line / to Clear in day mode
Format: 70MN0# Assign the extensions N outgoing to use the certain C.O.line (M) in
daytime.
70M0# All extensions can use co line M in day mode.
70M1# All extensions can not use co line M in day mode.
70MN1# to restrict the EXT.N to use C.O line M in day mode
70N2# Allow extension N use all C.O.lines in day mode.
70N3# to restrict EXT.N use all C.O.lines in day mode.
Summary of Contents for CDX-CP832
Page 1: ......