![P800 Solar Eclipse Manual Download Page 38](http://html.mh-extra.com/html/p800/solar-eclipse/solar-eclipse_manual_745128038.webp)
38
To verify the proper configuration of Solar Eclipse within the local network, open an Internet
browser through a PC connected to the local network and type http: // solareclipse000 or http:
//charger000 on the address bar.
If your network has correctly recognized the Solar Eclipse, and Solar Eclipse is powered by the
batteries, the following screen appears:
Figure 18 - Solar Eclipse configuration with browser
In case the RS485-USB cable is not available, you can also set the basic parameters from the
browser, simply by pressing the "store" button.
5.11
Fault search
SOLAR ECLIPSE DOES NOT SWITCH ON (with open DC disconnector of PV modules)
•
Verify with a volmeter that the voltage at the head of the Solar Eclipse board (+ batt / -
batt) is greater than 43 V and less than 55 V
•
If the voltage is ZERO, check that the external battery fuse is not interrupted
•
If the voltage is less than 43 V, charge the 48 V battery pack (with Solar Charger, Solar
Method, 12 V Battery Charger, etc ...)
•
If the voltage is greater than 55 V, check the battery pack connections (Warning: possible
damage to the Solar Eclipse!)